2014 IEEE Students' Conference on Electrical, Electronics and Computer Science 2014
DOI: 10.1109/sceecs.2014.6804463
|View full text |Cite
|
Sign up to set email alerts
|

Comparison of multicarrier PWM techniques for cascaded H-bridge inverter

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
7
0
1

Year Published

2016
2016
2021
2021

Publication Types

Select...
4
1
1

Relationship

1
5

Authors

Journals

citations
Cited by 23 publications
(8 citation statements)
references
References 20 publications
0
7
0
1
Order By: Relevance
“…Voltage and current quality for three-phase CHB inverters with equal DC sources for LS PWM are reported in the literature to be better than for PS PWM [13][14][15]. The presented frequency domain explanations seem to be complicated as they involve double Fourier series spectra calculations, sideband frequencies, etc.…”
Section: Current Thd For a Three-phase Chb Inverter With Non-equal DCmentioning
confidence: 99%
“…Voltage and current quality for three-phase CHB inverters with equal DC sources for LS PWM are reported in the literature to be better than for PS PWM [13][14][15]. The presented frequency domain explanations seem to be complicated as they involve double Fourier series spectra calculations, sideband frequencies, etc.…”
Section: Current Thd For a Three-phase Chb Inverter With Non-equal DCmentioning
confidence: 99%
“…When an MLI consists of multiple power sources and if each input source contributes equal power to the load then the power distribution among the sources is said to be 'even'. It is also called as 'charge balance control' or 'equal load sharing' [38]. Even power distribution can't be achieved in all topologies but is a feature of control only when the topology permits so.…”
Section: ) Even Power Distributionmentioning
confidence: 99%
“…It consists of three H-bridge converter cells connected in series, allowing the output voltage to be three times the DC source voltage of each cell. The modulation is accomplished with the phase shifted PWM as shown in [20]. With this topology, the effective inverter switching frequency is six times higher than the device switching frequency of each cell.…”
Section: A Topology Descriptionmentioning
confidence: 99%
“…The gains can be obtained as (20) with the same procedure as for the voltage control design. To define the control ability of the DC voltage on the CUT, the control strategy is mathematically analyzed in Table I, where C and I Cmax are the required values and L and V S are the designed values for satisfying the requirements mentioned in this section.…”
Section: B Control Strategy and Analysismentioning
confidence: 99%