Comparison of noninvasive continuous arterial waveform analysis (Nexfin) with transthoracic Doppler echocardiography for monitoring of cardiac output

Abstract: Considering limits of precision of CO measurements with Doppler echocardiography (± 30%), the agreement between noninvasive CO measurement with the Nexfin and TTE is reasonable.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

3
35
2
1

Year Published

2013
2013
2020
2020

Publication Types

Select...
6
2

Relationship

0
8

Authors

Journals

citations
Cited by 66 publications
(41 citation statements)
references
References 27 publications
3
35
2
1
Order By: Relevance
“…23) Another noninvasive arterial waveform analysis can be obtained using a Nexfin (BMEYE, Amsterdam, The Netherlands). 24) Compared to transthoracic Doppler echocardiography, the r correlation coeffi cient was 0.68 and appeared to be in line with our result. However, the bias was lower, only 0.51 L/minute and the 95% limit of agreement ranged from -1.6 to 2.6 L/minute.…”
Section: Discussionsupporting
confidence: 89%
“…23) Another noninvasive arterial waveform analysis can be obtained using a Nexfin (BMEYE, Amsterdam, The Netherlands). 24) Compared to transthoracic Doppler echocardiography, the r correlation coeffi cient was 0.68 and appeared to be in line with our result. However, the bias was lower, only 0.51 L/minute and the 95% limit of agreement ranged from -1.6 to 2.6 L/minute.…”
Section: Discussionsupporting
confidence: 89%
“…We did not perform a level of agreement analysis of our findings, obtained by the Nexfin monitor, with a gold standard. However, we and others previously showed that Nexfin arterial blood pressure and cardiac output showed good agreement with intra-arterial or oesophageal Doppler measurements [17,30,31].…”
Section: Discussionsupporting
confidence: 55%
“…In this study, we used the non-invasive Nexfin monitor for haemodynamic measurements. It measures continuous arterial blood pressure and subsequently calculates CO [5,13,[16][17][18][19][20][21][22] and PPV [5,11,13,23,24] from the arterial pressure waveform. It is restricted to patients with normal peripheral perfusion, and several studies have reported on its limited value in critically ill patients or during septic shock [25,26].…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…Other studies have also reported favourably on the Nexfin's ability to measure cardiac output accurately, e.g., compared with rebreathing methods, 111 or with transthoracic Doppler. 112 These results contrast with other studies that reported far inferior performance of the Nexfin device when comparing the noninvasively derived cardiac output measurements with thermodilution in critically ill patients 113,114 and cardiac ultrasound. 115 It is important to point out that, relative to other noninvasive cardiac output devices (e.g., over 3,000 patients in 16 studies comparing the FloTrac [uncalibrated] with thermodilution, over 1,400 patients in nine studies comparing the PiCCO [calibrated] with thermodilution, and almost 400 patients in three studies comparing the LiDCO [calibrated] with thermodilution), 107 there are very few data comparing volume-clamp-based estimates of SV or cardiac output with gold standards.…”
Section: Technologic Principlescontrasting
confidence: 60%