2022
DOI: 10.4103/ijo.ijo_2433_21
|View full text |Cite
|
Sign up to set email alerts
|

Comparison of ocular biometry and refractive outcome between ANTERION and IOL Master 700

Abstract: Purpose: To assess the comparability of ocular biometry measurements and refractive outcomes between ANTERION and IOL Master 700. Methods: This comparative prospective study was conducted from December 2020 to February 2021. A total of 225 patients who had cataracts were enrolled for the study and different parameters such as anterior keratometry (Steep K, Flat K) with axis, Sim K, central corneal thickness (CCT), aqueous depth (AQD), lens thickness (LT), and axial leng… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

1
8
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
5
2

Relationship

0
7

Authors

Journals

citations
Cited by 8 publications
(9 citation statements)
references
References 19 publications
1
8
0
Order By: Relevance
“…Specifically, AL measurements are the average values of three scans in each of six meridians [ 5 ]. The reliability of this updated biometer has also been investigated and confirmed in previous studies [ 9 , 10 ].…”
Section: Introductionsupporting
confidence: 77%
See 1 more Smart Citation
“…Specifically, AL measurements are the average values of three scans in each of six meridians [ 5 ]. The reliability of this updated biometer has also been investigated and confirmed in previous studies [ 9 , 10 ].…”
Section: Introductionsupporting
confidence: 77%
“…Besides the evident advance in optical biometry in recent years, new systems are continuously being developed using different optical principles which must be clinically validated. Considering the IOL Master platform as the gold standard [ 3 ], as previously mentioned, most studies investigating the reliability of new optical biometers are based on comparisons with such platforms [ 4 , 5 , 6 , 10 , 11 , 12 , 13 ]. Recently, a new optical biometer, VEMoS-AXL (CSO, Firenze, Italy), based on spectral-domain OCT (SD-OCT) has been developed.…”
Section: Introductionmentioning
confidence: 99%
“…SS-OCT was introduced in 2012, and since then its popularity has grown exponentially due to its remarkable advantages, resulting in the production of images of complex internal structures, such as those of the human eye, in a very high resolution. [7,[10][11][12][19][20][21]24,[27][28][29]. SS-OCT allows imaging of the vitreous, choroid, and retina, tissues that are small in size and therefore difficult to image, which is an advantage of primary importance in cataract surgery [19][20][21]25,[28][29][30].…”
Section: Discussionmentioning
confidence: 99%
“…[7,[10][11][12][19][20][21]24,[27][28][29]. SS-OCT allows imaging of the vitreous, choroid, and retina, tissues that are small in size and therefore difficult to image, which is an advantage of primary importance in cataract surgery [19][20][21]25,[28][29][30]. ANTERION uses a 1300 nm wavelength light source with a scan rate of 50,000 scans/sec, a scan depth of 14 mm and an axial resolution of 10 mm.…”
Section: Discussionmentioning
confidence: 99%
“…Second, reproducibility and reliability were not evaluated in the measurement of SS-OCT. However, the reproducibility and reliability of ANTERION SS-OCT has already been established in previous studies [ 5 , 26 , 42 44 ]. Additionally, we believe that the error that may occur was minimized due to the fact that all three acquisition quality parameters (“Motion,” “Fixation,” and “Tear film and lid”) were required to receive a "pass" result.…”
Section: Discussionmentioning
confidence: 99%