Abstract: Objectives: To assess agreement between measurements of ocular wavefront aberrations obtained using the Pentacam AXL Wave (Oculus Optikgeräte GmbH) (Aberrometer A) and KR-1W (Topcon Corp) (Aberrometer B), both of which are based on the Hartmann-Shack principle. Methods: In this prospective case-control study, ocular wavefront aberrations measurements were obtained using both aberrometers in patients with keratoconus (KC) and control participants. Ocular wavefront aberrations were measured through the natural p… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
5

Citation Types

0
6
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
5

Relationship

1
4

Authors

Journals

citations
Cited by 5 publications
(6 citation statements)
references
References 39 publications
0
6
0
Order By: Relevance
“…Asymmetric bowtie astigmatism can be seen as a combination of symmetric bowtie and coma, and only the former can be corrected by a toric IOL. The Hartman–Shack aberrometer is used in Pentacam to capture wavefront data at multiple locations [ 29 ]. The Hartman–Shack aberrometer has better repeatability than other sensor technologies [ 30 ].…”
Section: Discussionmentioning
confidence: 99%
“…Asymmetric bowtie astigmatism can be seen as a combination of symmetric bowtie and coma, and only the former can be corrected by a toric IOL. The Hartman–Shack aberrometer is used in Pentacam to capture wavefront data at multiple locations [ 29 ]. The Hartman–Shack aberrometer has better repeatability than other sensor technologies [ 30 ].…”
Section: Discussionmentioning
confidence: 99%
“…Recently, several researchers have reported on the repeatability and agreement of the device used herein compared to other devices for wavefront measurement. [19][20][21][22][23] Thus far, there have been two reports on wavefront analysis in KC using this wavefront aberrometer, but both are simple comparisons with healthy eyes. 21,23 Consistent with the result of our previous investigation that used an integrated Placido-disk topography system with a Hartmann-Shack wavefront aberrometer, 15 wavefront properties generally correlated with KC severity classified based on clinical and topographic signs.…”
Section: Discussionmentioning
confidence: 99%
“…[19][20][21][22][23] Thus far, there have been two reports on wavefront analysis in KC using this wavefront aberrometer, but both are simple comparisons with healthy eyes. 21,23 Consistent with the result of our previous investigation that used an integrated Placido-disk topography system with a Hartmann-Shack wavefront aberrometer, 15 wavefront properties generally correlated with KC severity classified based on clinical and topographic signs. Contrary to our expectations that we would detect abnormalities in the posterior cornea, the comprehensive wavefront assessment in this study did not show significant differences in wavefront properties between the VAE-NT and control eyes.…”