2007
DOI: 10.1016/j.arthro.2007.01.030
|View full text |Cite
|
Sign up to set email alerts
|

Comparison of Poly-L-Lactide and Polylactide Carbonate Interference Screws in an Ovine Anterior Cruciate Ligament Reconstruction Model

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
23
1

Year Published

2008
2008
2014
2014

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 28 publications
(24 citation statements)
references
References 34 publications
0
23
1
Order By: Relevance
“…5,2428 Sheep were selected for this study because their bone density and weight are similar to humans. 29 Pena et al 6 reported that bone density had an influence on determining peak loads at failure in human cadaveric specimens, so the use of sheep specimens can help to minimize specimen-related bias.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…5,2428 Sheep were selected for this study because their bone density and weight are similar to humans. 29 Pena et al 6 reported that bone density had an influence on determining peak loads at failure in human cadaveric specimens, so the use of sheep specimens can help to minimize specimen-related bias.…”
Section: Discussionmentioning
confidence: 99%
“…A modified semiquantitative scale, based on a previous study, was used to evaluate tendon-bone healing (Table 1). 24 The sections from each specimen were examined by 3 senior researchers blinded to group assignments, and the mean scores of the 3 researchers were used for statistical comparisons.…”
Section: Methodsmentioning
confidence: 99%
“…This bioabsorbable screw was composed of polylactide carbonate (PLC), an amorphous polymer consisting of 65% poly(D,L-lactic-co-glycolic acid) and 35% calcium carbonate 7,8 . It was hypothesized that this bioabsorbable material would also display osteoconductive properties, thereby providing a scaffold for new bone formation during its degradation.…”
mentioning
confidence: 99%
“…In ovine models [3], the PLC screws have shown gradual and controlled degradation, stimulating ossification of the graft within the bone tunnel. New bone thus formed was noted around the margin of the screw as early as 6–12 weeks.…”
Section: Discussionmentioning
confidence: 99%
“…Polylactide carbonate (PLC) is a combination of an amorphous bioabsorbable polymer, poly DL -lactide-coglycolide (PDLG), with calcium carbonate, a bone-stimulating material and neutralizing agent [3]. PLC was used to develop the “Calaxo” (Smith & Nephew, Andover, MA, USA) interference screw for knee ligament reconstruction surgery.…”
Section: Introductionmentioning
confidence: 99%