Comparison of Postoperative Refractive Outcomes: IOLMaster ® Versus Immersion Ultrasound

Abstract: IOLMaster biometry yields highly accurate results in cataract surgery. However, if the IOLMaster is unavailable, immersion ultrasound biometry with personalized intraocular lens constants is an acceptable alternative.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
6
0

Year Published

2013
2013
2024
2024

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 9 publications
(6 citation statements)
references
References 21 publications
0
6
0
Order By: Relevance
“…The AL has been measured using optical biometry and/or ultrasonography [ 1 7 ]. Optical biometry is the more accurate method for these measurements [ 8 ]. IOL Master (version 5; Carl Zeiss, Jena, Germany), an optical biometer that uses partial coherence interferometry (PCI) with the light source centered at 780 nm, is widely used.…”
Section: Introductionmentioning
confidence: 99%
“…The AL has been measured using optical biometry and/or ultrasonography [ 1 7 ]. Optical biometry is the more accurate method for these measurements [ 8 ]. IOL Master (version 5; Carl Zeiss, Jena, Germany), an optical biometer that uses partial coherence interferometry (PCI) with the light source centered at 780 nm, is widely used.…”
Section: Introductionmentioning
confidence: 99%
“…The precision in measurement of axial length by partial coherence interferometry technology, integrated automated keratometry function, and ease of operation are stated advantages of IOLMaster for standard biometry before cataract surgery. [11][12][13][14][15] The astigmatism measurement (meridian and power) by IOLMaster was not different from measurement using MK in our and others' studies. 16 However, the higher measurement of mean keratometric power with IOLMaster than with AK has previously raised concerns.…”
Section: Discussionmentioning
confidence: 91%
“…It provides different echotexture and echogenicity patterns according to the degree of acoustic impedance (BENTLEY et al, 2003;MATTOON ;NYLAND, 2015), as well as information on the position of cataracteous lenses (GAIDDON et al, 1991;MOLGAT et al, 1993;BENTLEY et al, 2003;SQUARZONI et al, 2007). B-mode ultrasounds also identify retinal detachment and vitreous degeneration (LABRUYERE et al 2008;PARK et al, 2015), which influence the decision-making process for surgical treatment (KUBAL, 2008;RAYMOND et al, 2009;WHANG et al, 2012). Additionally, B-mode ultrasounds measure lens thickness and length, allowing clinicians to choose the right size of artificial substitutes (BRANDÃO et al, 2007;LUYET et al, 2008;BARBÉ et al, 2017).…”
Section: Bidimensional Ultrasound (B-mode)mentioning
confidence: 99%