2015
DOI: 10.4103/2321-3825.150582
|View full text |Cite
|
Sign up to set email alerts
|

Comparison of rate of retraction and anchorage loss using nickel titanium closed coil springs and elastomeric chain during the en-masse retraction: A clinical study

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

3
26
0
7

Year Published

2017
2017
2022
2022

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 16 publications
(36 citation statements)
references
References 0 publications
3
26
0
7
Order By: Relevance
“…The characteristics of the included studies are shown (Table ). A total of 4 RCTs were included in this review, two RCTs presented with a split‐mouth design and two RCTs presented with a parallel‐group design . An a priori sample size calculation was performed in one study …”
Section: Resultsmentioning
confidence: 99%
See 2 more Smart Citations
“…The characteristics of the included studies are shown (Table ). A total of 4 RCTs were included in this review, two RCTs presented with a split‐mouth design and two RCTs presented with a parallel‐group design . An a priori sample size calculation was performed in one study …”
Section: Resultsmentioning
confidence: 99%
“…Two‐hundred grams of force was the mostly utilized force during space closure except in one RCT . Two RCTs reported the means of the outcomes without their respective standard deviations or standard errors. Although authors of these studies were contacted twice via email to provide information on the missing data, no response was obtained.…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…They are practical, efficient and of low cost, but they undergo progressive reduction in force magnitude and their properties are affected by humidity and temperature (10,11) . On the other hand, closed NiTi coil springs can be used as substitutes as they are superior to intermaxillary elastics in generating lower and more continuous forces that are affected to a lesser degree with humidity and pH (14,15) . No recent studies were found describing skeletal, dental and soft tissue effects of intermaxillary NiTi coil springs in Class II division treatment.…”
Section: Discussionmentioning
confidence: 99%
“…However, closed Nickel Titanium (NiTi) coil springs maybe a better substitute as they generate lower and more continuous forces that are affected to a lesser degree with humidity and pH. This characteristic of better force maintenance may cause faster and more physiologic movement with minimal aggression to dental and periodontal tissues (14,15) .…”
Section: Introductionmentioning
confidence: 99%