1995
DOI: 10.1016/s0022-3913(05)80134-9
|View full text |Cite
|
Sign up to set email alerts
|

Comparison of screw loosening, rotation, and deflection among three implant designs

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

4
116
1
50

Year Published

2011
2011
2024
2024

Publication Types

Select...
4
3
1

Relationship

0
8

Authors

Journals

citations
Cited by 153 publications
(171 citation statements)
references
References 4 publications
4
116
1
50
Order By: Relevance
“…Other studies also compared plastic, pre-machined and machined abutments and concluded that lower preload has developed for all components subjected to casting 15,21,30 . This study confirms such results and shows that casting procedures can decrease detorque values even in pre-machined cast abutments, like those used.…”
mentioning
confidence: 99%
See 1 more Smart Citation
“…Other studies also compared plastic, pre-machined and machined abutments and concluded that lower preload has developed for all components subjected to casting 15,21,30 . This study confirms such results and shows that casting procedures can decrease detorque values even in pre-machined cast abutments, like those used.…”
mentioning
confidence: 99%
“…This study confirms such results and shows that casting procedures can decrease detorque values even in pre-machined cast abutments, like those used. The reason seems to be the irregularities and roughness of contacting surfaces that may result from the casting process, which causes greater embedment relaxation and consequent preload loss 15,30 . The applied torque is distributed to the friction between the screw and the abutment, and between the threads of the screw and the implant, causing loosening.…”
mentioning
confidence: 99%
“…[20][21][22][23] The two-piece zirconia abutments also showed competitive results when compared to conventional titanium abutments. 22 A common complication of single or multiple implant restoration is screw loosening.…”
Section: Discussionmentioning
confidence: 98%
“…22 A common complication of single or multiple implant restoration is screw loosening. 23 Screw loosening may occasionally require mechanical repairs. Currently, there is a lack of studies with regard to abutment screw loosening in zirconia abutments with a secondary titanium component.…”
Section: Discussionmentioning
confidence: 99%
“…Screws were torqued at 32 N as recommended by the manufacturer. After 10 min, the specimens were torqued again (15).…”
Section: Methodsmentioning