2016
DOI: 10.1016/j.bjane.2014.07.011
|View full text |Cite
|
Sign up to set email alerts
|

Comparison of sevoflurane concentration for insertion of proseal laryngeal mask airway and tracheal intubation in children (correlation with BIS)

Abstract: We can conclude that in children airway can be secured safely with proseal laryngeal mask airway using less sevoflurane concentration in comparison to tracheal intubation and this was supported by BIS index.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

1
3
0
1

Year Published

2018
2018
2023
2023

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 7 publications
(5 citation statements)
references
References 11 publications
1
3
0
1
Order By: Relevance
“…Such high numbers of downrolling were witnessed during induction in our study because in general, induction with sevoflurane is rapid (alveolar concentration approaches inspired concentration much more rapidly) and because its flow to lungs is generally kept high during induction. The mean concentration of sevoflurane during induction at which EDEM/EDEP occurred prior to LMA insertion was high (median MAC = 2.65; IQR 2.28-3.0) which matched with other studies (8). In children, where it is common to use a volatile induction, sevoflurane is the preferred choice.…”
Section: Timing Of Onset Of Down-rolling During Ga During Inductionsupporting
confidence: 75%
“…Such high numbers of downrolling were witnessed during induction in our study because in general, induction with sevoflurane is rapid (alveolar concentration approaches inspired concentration much more rapidly) and because its flow to lungs is generally kept high during induction. The mean concentration of sevoflurane during induction at which EDEM/EDEP occurred prior to LMA insertion was high (median MAC = 2.65; IQR 2.28-3.0) which matched with other studies (8). In children, where it is common to use a volatile induction, sevoflurane is the preferred choice.…”
Section: Timing Of Onset Of Down-rolling During Ga During Inductionsupporting
confidence: 75%
“…Another potential risk expected was laryngospasm. We were able to avert this by maintaining adequate depth of anaesthesia with an ETS of 2.5 with 2 mcg/kg of fentanyl 11 12…”
Section: Discussionmentioning
confidence: 99%
“…In addition, it is used to adjust the number of anesthetic agents administered and reduce the recovery time from general anesthesia [ 26 ]. Certain studies have shown that BIS monitoring during anesthesia aids the reduction of the sevoflurane requirement and results in more rapid emergence from general anesthesia [ 29 ]. Chan et al reported that the titration of an anesthetic to maintain a BIS value between 40 and 60 during surgery could be used to avoid episodes of deep anesthesia, which was associated with a reduction in the risk of developing delirium [ 18 ].…”
Section: Discussionmentioning
confidence: 99%