2020
DOI: 10.1007/s11095-020-02801-3
|View full text |Cite
|
Sign up to set email alerts
|

Comparison of Signal Detection Algorithms Based on Frequency Statistical Model for Drug-Drug Interaction Using Spontaneous Reporting Systems

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
61
1

Year Published

2020
2020
2024
2024

Publication Types

Select...
7

Relationship

3
4

Authors

Journals

citations
Cited by 50 publications
(63 citation statements)
references
References 19 publications
1
61
1
Order By: Relevance
“…Therefore, to verify the accuracy of the subset analysis, we needed to prepare "hypothetical" true data of AEs. A previous comparative study [14] of five algorithms for detecting drug-drug interaction signals revealed that the Ω shrinkage measure model [16] detected the most conservative signal, while the combination risk ratio model [17] did not detect any interaction signal in less than three reports due to the detection criterion. Therefore, of the five algorithms, we used the combination of signals detected by the three algorithms (the additive model, the multiplicative model, and the chi-square statistical model) as "hypothetical" true data.…”
Section: Discussionmentioning
confidence: 99%
See 3 more Smart Citations
“…Therefore, to verify the accuracy of the subset analysis, we needed to prepare "hypothetical" true data of AEs. A previous comparative study [14] of five algorithms for detecting drug-drug interaction signals revealed that the Ω shrinkage measure model [16] detected the most conservative signal, while the combination risk ratio model [17] did not detect any interaction signal in less than three reports due to the detection criterion. Therefore, of the five algorithms, we used the combination of signals detected by the three algorithms (the additive model, the multiplicative model, and the chi-square statistical model) as "hypothetical" true data.…”
Section: Discussionmentioning
confidence: 99%
“…This study has the following three limitations. First, unfortunately, unknown AE data do not exist anywhere in the world [14]. Therefore, there were no "real" true data for AEs.…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations
“…We have already demonstrated that the Ω shrinkage measure 21 proposed by Norén et al detected the most conservative signals in a previous comparative study. 22 In this study, we used two signal search algorithms for searching the JADER database of spontaneous reports of AEs in Japan to detect a signal of each AED and drug interaction, and we evaluated the association between the onset of SJS and TEN and the AED combination therapies.…”
Section: Introductionmentioning
confidence: 99%