2022
DOI: 10.3390/antibiotics11030377
|View full text |Cite
|
Sign up to set email alerts
|

Comparison of Six Phenotypic Assays with Reference Methods for Assessing Colistin Resistance in Clinical Isolates of Carbapenemase-Producing Enterobacterales: Challenges and Opportunities

Abstract: The global escalation of severe infections due to carbapenemase-producing Enterobacterales (CPE) isolates has prompted increased usage of parenteral colistin. Considering the reported difficulties in assessing their susceptibility to colistin, the purpose of the study was to perform a comparative evaluation of six phenotypic assays—the colistin broth disc elution (CBDE), Vitek 2 Compact (bioMérieux SA, Marcy l’Etoile, France), the Micronaut MIC-Strip Colistin (Merlin Diagnostika GMBH, Bornheim-Hensel, Germany)… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

2
11
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
6

Relationship

1
5

Authors

Journals

citations
Cited by 8 publications
(13 citation statements)
references
References 58 publications
2
11
0
Order By: Relevance
“…Consequently, in the first case, a combination of mutations in mgrB (M27K), phoP (L4F), and phoQ (Q426L) genes was noted, while in the second case, an L26Q substitution in the phoQ gene was associated with R256G mutation in the pmrB gene. However, several reports have mentioned that Vitek 2 Compact is inappropriate for colistin susceptibility testing [ 63 , 64 , 65 ], especially for strains showing an MIC > 1 mg/L by BMD [ 63 ]. The manufacturer of Vitek 2 Compact has also recommended using an alternative method prior to reporting colistin results obtained with several types of testing cards in this automated system [ 66 ], at least until this issue can be addressed through technology upgrades to be implemented in the future.…”
Section: Discussionmentioning
confidence: 99%
See 4 more Smart Citations
“…Consequently, in the first case, a combination of mutations in mgrB (M27K), phoP (L4F), and phoQ (Q426L) genes was noted, while in the second case, an L26Q substitution in the phoQ gene was associated with R256G mutation in the pmrB gene. However, several reports have mentioned that Vitek 2 Compact is inappropriate for colistin susceptibility testing [ 63 , 64 , 65 ], especially for strains showing an MIC > 1 mg/L by BMD [ 63 ]. The manufacturer of Vitek 2 Compact has also recommended using an alternative method prior to reporting colistin results obtained with several types of testing cards in this automated system [ 66 ], at least until this issue can be addressed through technology upgrades to be implemented in the future.…”
Section: Discussionmentioning
confidence: 99%
“…Remarkably, another significant aspect of our study is the molecular basis of the two pairs of ChR (parental and the corresponding resistant mutants) isolates, which are reported for the first time in Romania [ 65 ]. These two pairs of strains co-harbored an mgrB alteration caused by an ISKpn25 element insertion at the same position (with the deletion of nucleotides 1–5) and an R256G substitution in pmrB .…”
Section: Discussionmentioning
confidence: 99%
See 3 more Smart Citations