2012
DOI: 10.1016/j.ab.2012.08.015
|View full text |Cite
|
Sign up to set email alerts
|

Comparison of Stain-Free gels with traditional immunoblot loading control methodology

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

2
119
0
4

Year Published

2013
2013
2021
2021

Publication Types

Select...
9
1

Relationship

0
10

Authors

Journals

citations
Cited by 125 publications
(125 citation statements)
references
References 7 publications
2
119
0
4
Order By: Relevance
“…Stain-free imaging of the gels and membranes, corresponding to proteins in the samples, was used as loading control and for normalization. 62 Proteins were transferred to a nitrocellulose membrane using a Trans-Blot Turbo system (BioRad). They were then probed with a polyclonal goat anti-apoE antibody (1 : 800; AB947, Millipore), washed, and probed with HRP-conjugated horse anti-goat IgG (1 : 3000; Bio-Rad).…”
Section: Methodsmentioning
confidence: 99%
“…Stain-free imaging of the gels and membranes, corresponding to proteins in the samples, was used as loading control and for normalization. 62 Proteins were transferred to a nitrocellulose membrane using a Trans-Blot Turbo system (BioRad). They were then probed with a polyclonal goat anti-apoE antibody (1 : 800; AB947, Millipore), washed, and probed with HRP-conjugated horse anti-goat IgG (1 : 3000; Bio-Rad).…”
Section: Methodsmentioning
confidence: 99%
“…This is further complicated by the fact that some detection methods, in particular enhanced chemiluminescence using x-ray film, have a very restricted linear range, and careful attention to the experimental conditions is necessary to ensure linearity. It is typically better to normalize Western blots using total protein loading as the denominator (3)(4)(5)(6)(7)(8)(9)(10)(11). To avoid potential pitfalls and with a focus on improving transparency, the JBC strongly recommends that authors describe their methods used to quantify signal intensity, how the linearity of signal intensity with antigen loading was established, and how protein loading was normalized between lanes.…”
Section: Presentation and Quantitation Of Western Blotsmentioning
confidence: 99%
“…Some researchers have stained the blots with total protein stains, such as Coomassie, Flamingo Pink, Sypro Ruby, Amido Black, Ponceau S, and stain-free technology, to measure the total protein signal in each lane as loading control 16,20,13,27,1,4,12 . The total protein loading control avoids the pitfalls associated with housekeeping proteins.…”
mentioning
confidence: 99%