2011
DOI: 10.1002/jmri.23518
|View full text |Cite
|
Sign up to set email alerts
|

Comparison of T1‐weighted in‐ and out‐of‐phase single shot magnetization‐prepared gradient‐recalled‐echo with three‐dimensional gradient‐recalled‐echo at 3.0 tesla: Preliminary observations in abdominal studies

Abstract: Purpose: To describe in-phase (IP)/out-of-phase (OP) imaging with single shot magnetization-prepared gradient-recalled-echo (MP-GRE) and to compare intra-individually IP/OP MP-GRE with IP/OP three-dimensional gradient-recalled-echo (3D-GRE) at 3.0 Tesla (T). Materials and Methods:Thirty-six subjects (15 males, 21 females; mean age 46.97 6 14.97) who had abdominal MRI examinations including precontrast T1-weighted IP/ OP MP-GRE, IP/OP 3D-GRE were included in the study. Two radiologists independently evaluated t… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

2012
2012
2015
2015

Publication Types

Select...
4
2

Relationship

0
6

Authors

Journals

citations
Cited by 7 publications
(3 citation statements)
references
References 29 publications
0
3
0
Order By: Relevance
“…Dual GE IP/OP imaging is performed as multiline GE acquisitions that require patients to suspend their respiration as the sequences are generally 10–20 seconds in duration. A new application of MP-RAGE IP/OP images is able to substitute standard dual GR IP/OP imaging with moderate image quality in the elderly, severely debilitated, and in young children (Figure 1) [57]. MP-RAGE operates as a slice-by-slice, single-shot technique used during free breathing.…”
Section: Mr Imaging Sequencesmentioning
confidence: 99%
See 1 more Smart Citation
“…Dual GE IP/OP imaging is performed as multiline GE acquisitions that require patients to suspend their respiration as the sequences are generally 10–20 seconds in duration. A new application of MP-RAGE IP/OP images is able to substitute standard dual GR IP/OP imaging with moderate image quality in the elderly, severely debilitated, and in young children (Figure 1) [57]. MP-RAGE operates as a slice-by-slice, single-shot technique used during free breathing.…”
Section: Mr Imaging Sequencesmentioning
confidence: 99%
“…They are seen at the interface between hepatic vessels and hepatic parenchyma. Notwithstanding these disadvantages, only MP-RAGE IP/OP sequence would be applicable for acquisition of chemical shift imaging in an usual clinical setting, when 2D-GRE is not feasible or might generate nondiagnostic images, such as in the case of uncooperative patients and pediatrics [5]. …”
Section: Mr Imaging Sequencesmentioning
confidence: 99%
“…Similar to other imaging techniques, homogeneous opacification and adequate luminal distention of the small bowel is desirable since poorly distended loops can simulate disease 23 or hide pathologic processes especially in less experienced hands.…”
Section: Technical Considerationsmentioning
confidence: 99%