2014
DOI: 10.1016/j.joen.2014.04.014
|View full text |Cite
|
Sign up to set email alerts
|

Comparison of the Accuracy of 3-dimensional Cone-beam Computed Tomography and Micro–Computed Tomography Reconstructions by Using Different Voxel Sizes

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
52
1
14

Year Published

2015
2015
2022
2022

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 59 publications
(67 citation statements)
references
References 22 publications
0
52
1
14
Order By: Relevance
“…CBCT images allow the acquisition of 3-dimensional images of dentin bridges and enable their qualitative assessment (24,26,28). The results of our study showed that Ca(OH) 2 , MTA, Biodentine, and Single Bond Universal had different degrees of influence on dentin bridge formation, with the former 3 positively affecting the exposed pulp and actively initiating the formation of reparative dentin in each tooth and the latter one resulting in the formation of significantly lesser dentin bridges of a Clinical Research lower quality, thickness, and volume.…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations
“…CBCT images allow the acquisition of 3-dimensional images of dentin bridges and enable their qualitative assessment (24,26,28). The results of our study showed that Ca(OH) 2 , MTA, Biodentine, and Single Bond Universal had different degrees of influence on dentin bridge formation, with the former 3 positively affecting the exposed pulp and actively initiating the formation of reparative dentin in each tooth and the latter one resulting in the formation of significantly lesser dentin bridges of a Clinical Research lower quality, thickness, and volume.…”
Section: Discussionmentioning
confidence: 99%
“…Although the CBCT diagnostics used in this study have sensitivity lower than that of light microscopy, they can provide additional information on tertiary dentin mineralization (24,26,28). The authors observed regions with different levels of mineralization on CBCT images, which is not possible in demineralized histologic sections.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…Given the fact that the voxel size is another affecting parameter, adjusting the setting to a higher scan resolution could compensate the effect of soft tissue presence. Concerning this parameter, it has been indicated that the accuracy of the models appears to be connected to the voxel size [49], although the differences were small. However, others did not find increased accuracy of linear measurements on segmented surface models decreasing the voxel size from 0.4 to 0.25 mm [34].…”
Section: Discussionmentioning
confidence: 99%
“…However, the latest CBCT apparatuses now permit scans with isotropic voxel resolutions down to 80 µm [55] or 76 µm [56] (Fig. 2c).…”
Section: Cone-beam Computed Tomographymentioning
confidence: 99%