2021
DOI: 10.15835/buasvmcn-vm:2020.0038
|View full text |Cite
|
Sign up to set email alerts
|

Comparison of the Cytology Brush and Low Volume Lavage Techniques to Evaluate Endometrial Cytology for Diagnosing Endometritis in Chronically Infertile Mares

Abstract: Endometritis is the most common cause of subfertility and infertility in mares that leads to great economical loss. Endometrial cytology (EC) is a reliable diagnostic tool, widely used to assess the health of the reproductive tract in both humans and domestic mammals. The aim of this study was to compare two techniques for the collection of EC samples in chronically infertile mares. Ten mares aged 4 to 20 were used. In each mare, samples for EC were collected first by cytology brush (CB) and then by low volume… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

2024
2024
2024
2024

Publication Types

Select...
1

Relationship

0
1

Authors

Journals

citations
Cited by 1 publication
(3 citation statements)
references
References 12 publications
0
3
0
Order By: Relevance
“…The CB specimens obtained in the field exhibited superior preservation of both quantity and quality of cells for cytological analysis compared to those obtained from the same brush after transport to the lab in a sterile saline solution. Low-volume flushes, CBs, and CSs have been validated for the cytological evaluation of the endometrium in mares [ 4 , 11 , 16 , 17 ]. Moreover, the use of a double-guarded CB has been demonstrated to improve diagnostic accuracy for endometrial cytology in mares and women [ 5 , 8 , 11 , 12 , 21 , 31 ].…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations
“…The CB specimens obtained in the field exhibited superior preservation of both quantity and quality of cells for cytological analysis compared to those obtained from the same brush after transport to the lab in a sterile saline solution. Low-volume flushes, CBs, and CSs have been validated for the cytological evaluation of the endometrium in mares [ 4 , 11 , 16 , 17 ]. Moreover, the use of a double-guarded CB has been demonstrated to improve diagnostic accuracy for endometrial cytology in mares and women [ 5 , 8 , 11 , 12 , 21 , 31 ].…”
Section: Discussionmentioning
confidence: 99%
“…Cytological slides prepared immediately after collection had more background, red blood cell contamination, and more intact endometrial and inflammatory cells than LS and PS. The presence of mucus and debris, including degenerated neutrophils, destroyed epithelial cells, and inflammatory residue, in the background of cytological samples may indicate a trace of inflammation and has been consistently associated with positive cultures [ 16 , 17 , 31 ]. The use of the novel cytotape technique demonstrated less blood contamination than the samples collected using a CB [ 14 ].…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation