Comparison of the mouse spleen cell assay and a radioimmunoassay for the measurement of serum erythropoietin

Abstract: The mouse spleen cell assay (MSCA) has been compared with a radioimmunoassay for the measurement of serum erythropoietin (Ep). In 20 normal subjects the serum values ranged from 15 to 73 mU/ml for the MSCA compared with 5-30 mU/ml for the RIA. For normal sera there was no correlation between the results of the two assays. In 37 patients with anaemias of differing aetiologies and at various stages of treatment values ranged from 10 to 3645 mU/ml for the MSCA and 13-10,000 mU/ml for the RIA. Although patient val… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
11
0

Year Published

1989
1989
1999
1999

Publication Types

Select...
5
2

Relationship

1
6

Authors

Journals

citations
Cited by 30 publications
(11 citation statements)
references
References 9 publications
0
11
0
Order By: Relevance
“…This probably reflects the influence of the impurities in these materials on the cultured assay cells, which may be greatest for CFUe assays because both rates of growth and differentia¬ tion are measured. These in-vitro bioassays are there¬ fore not readily applicable to the assay of serum EPO without some prior extraction procedure (Lappin, Elder, Taylor et al 1988;Wognum, Lam, Goudsmit & Krystal, 1990).…”
Section: Comparisons Of Epo Assay Methodsmentioning
confidence: 99%
“…This probably reflects the influence of the impurities in these materials on the cultured assay cells, which may be greatest for CFUe assays because both rates of growth and differentia¬ tion are measured. These in-vitro bioassays are there¬ fore not readily applicable to the assay of serum EPO without some prior extraction procedure (Lappin, Elder, Taylor et al 1988;Wognum, Lam, Goudsmit & Krystal, 1990).…”
Section: Comparisons Of Epo Assay Methodsmentioning
confidence: 99%
“…Umbilical arterial cord blood was sampled and used to measure levels of Epo, haemoglobin, haematocrit and blood gases. Se rum was immediately separated by centrifugation and stored at -70 °C until Epo levels were estimated by radio-immunoassay [17]. Briefly, the method involved a disequilibrium assay, using l25I-labelled Epo (Amersham International PLC, Amersham, UK) and rabbit anti-Epo antibody.…”
Section: Methodsmentioning
confidence: 99%
“…Briefly, the method involved a disequilibrium assay, using l25I-labelled Epo (Amersham International PLC, Amersham, UK) and rabbit anti-Epo antibody. Batches of 20 serum samples were assayed under a protocol which required 4 days for completion [17], Blood gases and pH were measured immediately using an automated Corning blood gas analyser. Correlation coefficients were calculated by the method of differences between least squares.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…Epo was determined by radioimmunoassay [20] with some modifications. The method uses a disequilibrium system in which the addition of the labelled antigen is delayed for 3 days after the initial mixing of the test or standard Epo solutions with the antiEpo antibody.…”
Section: Radioimmunoassay For Epomentioning
confidence: 99%