2001
DOI: 10.2136/sssaj2001.652491x
|View full text |Cite
|
Sign up to set email alerts
|

Comparison of Three Aqua Regia Digestion Methods for Twenty Florida Soils

Abstract: soil and sludge samples based on it, in addition to the total elemental concentrations (Vercoutere et al., 1995; It is important to evaluate different digestion methods to accurately Quevauviller et al., 1993). In many countries (excluding determine elemental concentrations in soils. Three commonly used digestion procedures, hotplate aqua regia, microwave aqua regia, and the USA), this procedure is required by regulations to microwave aqua regia ϩ HF, were compared for digestion of three estimate the impact of… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

9
221
0
4

Year Published

2010
2010
2022
2022

Publication Types

Select...
7
3

Relationship

0
10

Authors

Journals

citations
Cited by 420 publications
(234 citation statements)
references
References 31 publications
9
221
0
4
Order By: Relevance
“…The selection of this method was based on the objective of estimating the environmental availability of trace elements. Thus, recovery of the Cr in the reference samples may be considered satisfactory when compared to the methods using HNO 3 , HCl, H 2 O 2 , and HF (Chen and Ma, 2001;Vieira et al, 2005).…”
Section: Resultsmentioning
confidence: 99%
“…The selection of this method was based on the objective of estimating the environmental availability of trace elements. Thus, recovery of the Cr in the reference samples may be considered satisfactory when compared to the methods using HNO 3 , HCl, H 2 O 2 , and HF (Chen and Ma, 2001;Vieira et al, 2005).…”
Section: Resultsmentioning
confidence: 99%
“…Total organic C and total N were analyzed by the dry combustion and micro-Kjeldahl method, respectively. Total elemental composition (P, K, Ca, Mg and S) was estimated in Aqua Regia (concentrated HCl-HNO 3 at 3:1 v/ v ratio) digested samples in an Inductively Coupled Plasma-Optical Emission Spectrophotometer (Varian 725ES model) (Chen and Ma 2001). The pH was recorded after suspending the feed-stocks and compost sample powders in deionized water (1:10 w/v) for 1 h using a pH meter.…”
Section: Sampling and Physico-chemical Analysismentioning
confidence: 99%
“…The Campbell et al (2008), to evaluate the quality of analytical method. The detection limits of ICP-MS were evaluated with respect to the protocols of Chen and Ma (2001) and were found to range between (0.0001 -0.1) mg/kg for the thirteen elements considered in this study. Two distinct indices were used in the assessment of the level of enrichment and ecological risk by PTEs contamination in the stream sediments of Okemesi-Ijero, southwestern, Nigeria.…”
Section: Collection Of Samplesmentioning
confidence: 99%