2017
DOI: 10.1016/j.jstrokecerebrovasdis.2017.06.029
|View full text |Cite
|
Sign up to set email alerts
|

Comparison of Three-Dimensional T1-Weighted Magnetic Resonance and Contrast-Enhanced Ultrasound Plaque Images for Severe Stenosis of the Cervical Carotid Artery

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
6
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
8
1

Relationship

2
7

Authors

Journals

citations
Cited by 11 publications
(6 citation statements)
references
References 25 publications
0
6
0
Order By: Relevance
“…A difference in imaging approach is present because neovascularization can be adequately studied with CT, MR and CE-US (57)(58)(59)(60)(61) whereas the IPH of coronary arteries nowadays can be actually explored only with OCT or IVUS (62)(63)(64).…”
Section: Plaque Composition: Neovascularization and Inflammationmentioning
confidence: 99%
“…A difference in imaging approach is present because neovascularization can be adequately studied with CT, MR and CE-US (57)(58)(59)(60)(61) whereas the IPH of coronary arteries nowadays can be actually explored only with OCT or IVUS (62)(63)(64).…”
Section: Plaque Composition: Neovascularization and Inflammationmentioning
confidence: 99%
“…e Schalk study found that, in terms of kidney volume measurement, three-dimensional ultrasound is better than two-dimensional ultrasound in terms of reproducibility, and three-dimensional ultrasound can more intuitively observe the shape and structure of the kidney [2]. Shimada used a low-MI continuous imaging method to obtain appropriate tissue suppression but at the same time maintain sufficient penetrating power, and placed the focus on the deep side of the observation target [3]. Green proposed that the kidney length includes renal sinus fat, which cannot truly reflect the size of functional renal tissue.…”
Section: Introductionmentioning
confidence: 99%
“…We reported that preoperative CEUS predicted micro-embolic signals on transcranial Doppler during carotid artery exposure in 70 patients who were candidates for CEA with a sensitivity of 90% and specificity of 76% [80]. We also reported that the signal intensity of plaques on MRI was associated with the contrast effect on CEUS in patients with severe carotid artery stenosis (≥70%) [81]. In a retrospective study of 71 patients with TA undergoing carotid CEUS, a significant correlation was found between the CEUS results and clinical disease activity [82].…”
Section: Contrast-enhanced Ultrasonography (Ceus)mentioning
confidence: 85%