Comparison of Three Prototypes of PPG Sensors for Continual Real-Time Measurement in Weak Magnetic Field

Abstract: This paper is focused on investigation of three developed prototypes of sensors based on the photoplethysmography (PPG) principle for continual measurement of the PPG signal in the magnetic field environment with the inherent radiofrequency and electromagnetic disturbance. The tested prototypes differ in the used optical part of the PPG sensor and their working mode, control unit, power supply, and applied Bluetooth (BT) communication methods. The main aim of the current work was motivated by finding suitable … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
5
0

Year Published

2022
2022
2023
2023

Publication Types

Select...
2
2

Relationship

1
3

Authors

Journals

citations
Cited by 4 publications
(5 citation statements)
references
References 23 publications
0
5
0
Order By: Relevance
“…A PPG sensor measures changes in blood flow by placing a light source and a photodetector on the skin's surface. The PPG signal has recently attracted the attention of several academics interested in extracting further data from it [48]. The PPG signal's second derivative wave carries crucial diagnostic information.…”
Section: Ppg Sensorsmentioning
confidence: 99%
“…A PPG sensor measures changes in blood flow by placing a light source and a photodetector on the skin's surface. The PPG signal has recently attracted the attention of several academics interested in extracting further data from it [48]. The PPG signal's second derivative wave carries crucial diagnostic information.…”
Section: Ppg Sensorsmentioning
confidence: 99%
“…Additionally, in many practical cases, lower-sampling-rate PPG data are used [ 45 , 46 , 47 ]. To broaden the applicability of this study, collected PPG recordings were two- and four-times subsampled to generate sparse PPG time series.…”
Section: Datamentioning
confidence: 99%
“…Examples of the resulting time series obtained using the original (𝜃 = 0) and noisy (𝜃 = 0.25) x time series are shown in Figure 3, where the addition of dynamical noise affected the amplitude of the time series and created additional fluctuations compared to the original time series. Additionally, in many practical cases, lower-sampling-rate PPG data are used [45][46][47].…”
Section: Simulated Datamentioning
confidence: 99%
“…Age and gender as well as skin color and the temperature of the skin surface can have an influence on the PPG signal, too. Our previous solution of wearable PPG sensors [7] does not allow direct temperature measurement by any contact thermo-element during the PPG signal sensing. For precise determination of PPG wave parameters, the current temperature should be measured at the same time as the PPG signal is sensed.…”
Section: Introductionmentioning
confidence: 99%
“…In addition, we try to formulate a recommendation about a proper arrangement and timing of PPG signal sensing to obtain the desired PPG parameters with a sufficient accuracy. Described firststep experiments were realized in normal laboratory conditions, with planned further application for measurements inside a running low-field MRI device [7,8].…”
Section: Introductionmentioning
confidence: 99%