2018
DOI: 10.1007/s12028-018-0608-7
|View full text |Cite
|
Sign up to set email alerts
|

Comparison of Two Apnea Test Methods, Oxygen Insufflation and Continuous Positive Airway Pressure During Diagnosis of Brain Death: Final Report

Abstract: The results from the study show that I-AT may compromise pulmonary function in some cases and is one of the reasons for the recommendation of a safer option, CPAP-AT, in the currently revised Polish BD criteria. During AT, the mean CO increase rate was 5 mmHg/min, which, in most patients, would allow the test to be completed after just 5 min.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
11
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 14 publications
(12 citation statements)
references
References 20 publications
1
11
0
Order By: Relevance
“…The 2010 AAN guidelines and the Austrian guidelines support AT with a T-piece and CPAP (second approach) if conventional AT resulted in poor oxygenation [4,14]. Contrastingly, the Polish criteria recommend routine use of CPAP on a ventilator (CPAP-AT) [15]. These techniques can prevent the decruitment of lungs, reduce the risk of hypoxemia, and increase hemodynamic stability by prevention of blood pressure fluctuation compared to the traditional O 2 insufflation method.…”
Section: Modified At With Maintenance Of Positive End-expiratory Presmentioning
confidence: 99%
See 3 more Smart Citations
“…The 2010 AAN guidelines and the Austrian guidelines support AT with a T-piece and CPAP (second approach) if conventional AT resulted in poor oxygenation [4,14]. Contrastingly, the Polish criteria recommend routine use of CPAP on a ventilator (CPAP-AT) [15]. These techniques can prevent the decruitment of lungs, reduce the risk of hypoxemia, and increase hemodynamic stability by prevention of blood pressure fluctuation compared to the traditional O 2 insufflation method.…”
Section: Modified At With Maintenance Of Positive End-expiratory Presmentioning
confidence: 99%
“…In series of 4 and 26 BD patients by the same group, an Ambu bag with a PEEP valve was connected to the ETT with 10 L/min of 100% oxygen flow upon ventilator disconnection, resulting in stable PaO 2 /FiO 2 (P/F) ratio when compared to prior to AT [17,18]. In a recent comparison of the classic oxygen insufflation method with the CPAP-AT in 60 patients, a gradual decrease of P/F ratio was found throughout conventional AT, but not in the CPAP group [15]. In a Korean study comparing MAT to conventional AT, mean duration of AT was similar, without significant differences in change of PaCO 2 , PaO 2 or pH.…”
Section: Modified At With Maintenance Of Positive End-expiratory Presmentioning
confidence: 99%
See 2 more Smart Citations
“…Low blood pressure, arrhythmias, and/or hypoperfusion, which may lead to interrupting the test and impairment of organ function are mentioned. This condition may impact the quality and survival of the organs to be donated [3]. In this trial, we aimed to assess the safety of ATs in patients undergoing a BD protocol.…”
Section: Introductionmentioning
confidence: 99%