Comparison of Two High-End Ultrasound Systems for Contrast-Enhanced Ultrasound Quantification of Mural Microvascularity in Crohn’s Disease

Abstract: Due to multiple uncontrollable affecting factors, the method of CEUS quantification by VueBox in the intestine cannot be recommended for device-independent multicenter studies. Therefore we suggest to use identical ultrasound systems and probes as well as to establish adequate reference ROIS, like a AIF-ROI.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
23
0
1

Year Published

2017
2017
2019
2019

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 26 publications
(24 citation statements)
references
References 19 publications
0
23
0
1
Order By: Relevance
“…We therefore recommend that curve fitting quality should be reported alongside test results in future publications. Also, using low perfused tissue as a reference will cause high uncertainty of the final results [40].…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…We therefore recommend that curve fitting quality should be reported alongside test results in future publications. Also, using low perfused tissue as a reference will cause high uncertainty of the final results [40].…”
Section: Discussionmentioning
confidence: 99%
“…However, based on the present findings within patient repeatability seems acceptable for the clinical use of CEUS in CD, especially when applying strict criteria for size and QoF. Lack of strict criteria or the use of a low perfused tissue as the reference tissue will lead to poor reproducibility [35,40]. We chose to restrict the inclusion of patients to those with moderate to severe disease activity based on clinical symptoms.…”
Section: P-valuementioning
confidence: 93%
“…Last but not least, additional ultrasound modalities, for instance, CEUS, which focuses on blood vessel delineation, would be meaningful. 19,37…”
Section: Discussionmentioning
confidence: 99%
“…As mentioned in the introduction, only one study has previously addressed the variability of measurements between scanners [10]. They used the Vuebox software which analyzes time intensity curves.…”
Section: Discussionmentioning
confidence: 99%
“…Briefly summarized, differences in settings of the ultrasound scanner, patient characteristics, injection technique, ultrasound contrast behavior, presence of large vessels in the ROI, region selection and tissue motion are all factors that may introduce variability [5][6][7][8]. Studies with strict standardization criteria show promising results [9], while there is high variability and low reproducibility when attempts are made to compare different equipment [10].…”
Section: Introductionmentioning
confidence: 99%