2018
DOI: 10.2147/opth.s152201
|View full text |Cite
|
Sign up to set email alerts
|

Comparison of two laboratory-based systems for evaluation of halos in intraocular lenses

Abstract: PurposeMultifocal intraocular lenses (IOLs) can be associated with unwanted visual phenomena, including halos. Predicting potential for halos is desirable when designing new multifocal IOLs. Halo images from 6 IOL models were compared using the Optikos modulation transfer function bench system and a new high dynamic range (HDR) system.Materials and methodsOne monofocal, 1 extended depth of focus, and 4 multifocal IOLs were evaluated. An off-the-shelf optical bench was used to simulate a distant (>50 m) car hea… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2

Citation Types

1
3
0

Year Published

2018
2018
2024
2024

Publication Types

Select...
4
1
1

Relationship

0
6

Authors

Journals

citations
Cited by 7 publications
(4 citation statements)
references
References 19 publications
1
3
0
Order By: Relevance
“…In addition, when the PDF lens was combined with a converging lens, the results showed a definite multifocal function: far objects appeared slightly blurry compared with a monofocal lens. These findings are similar to those using diffractive multifocal IOLs [ 10 16 ].…”
Section: Discussionsupporting
confidence: 88%
“…In addition, when the PDF lens was combined with a converging lens, the results showed a definite multifocal function: far objects appeared slightly blurry compared with a monofocal lens. These findings are similar to those using diffractive multifocal IOLs [ 10 16 ].…”
Section: Discussionsupporting
confidence: 88%
“…These ndings are similar to those using diffractive multifocal IOLs. [9][10][11][12][13][14][15] In this study, we used a converging f = 50 mm lens and a PDF lens with f = + /-100 mm. The PDF lens with f = + /-100 mm was commercially available with the longest focal length.…”
Section: Discussionmentioning
confidence: 99%
“…Although it is the primary complaint of patients with multifocal IOLs, dysphotopsia is only noted in 29% of patients and 95% of patients with otherwise healthy eyes can see with 20/40 vision after cataract surgery and 51% have 20/20 vision. [3] Unfortunately, multifocal contact lenses have faced more issues. It takes multiple days to fit multifocal contact lenses and the success rate of patients sticking with multifocal lenses after 3 months is between 67 and 83 percent.…”
Section: Introductionmentioning
confidence: 99%