Comparison of wear and temperature of zirconia and tungsten carbide tools in drilling bone: in vitro and finite element analysis

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
18
1

Year Published

2020
2020
2022
2022

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 24 publications
(19 citation statements)
references
References 23 publications
0
18
1
Order By: Relevance
“…In case of external irrigation sequences, constant saline cooling of 50 ml/min at room temperature (Ecobag ® click, 0.9% NaCl, 5,000 ml, B. Braun Melsungen AG, Melsungen, Germany) was applied throughout the whole preparation period (drilling start to withdrawing end) using an irrigation tubing set (Irrigation set for machinery—80 mm, 32.F0139, Omnia ® , Fidenza, Italy) and surgical suction was applied at 1.5 cm from preparation site. All osteotomies were performed according to a standard protocol for an atraumatic preparation at 800 rpm (Gaspar et al., 2013; Koopaie et al., 2019; Oliveira et al., 2012; Scarano et al., 2020; Strbac et al., 2015; Strbac, Giannis, et al., 2014; Strbac, Unger, et al., 2014).…”
Section: Methodsmentioning
confidence: 99%
“…In case of external irrigation sequences, constant saline cooling of 50 ml/min at room temperature (Ecobag ® click, 0.9% NaCl, 5,000 ml, B. Braun Melsungen AG, Melsungen, Germany) was applied throughout the whole preparation period (drilling start to withdrawing end) using an irrigation tubing set (Irrigation set for machinery—80 mm, 32.F0139, Omnia ® , Fidenza, Italy) and surgical suction was applied at 1.5 cm from preparation site. All osteotomies were performed according to a standard protocol for an atraumatic preparation at 800 rpm (Gaspar et al., 2013; Koopaie et al., 2019; Oliveira et al., 2012; Scarano et al., 2020; Strbac et al., 2015; Strbac, Giannis, et al., 2014; Strbac, Unger, et al., 2014).…”
Section: Methodsmentioning
confidence: 99%
“…53,138 Despite the dominant influences of drill bit wear on bone damage, the guidelines regarding this topic in bone drilling have yet to be established. 131 Many studies have reported the effects of drill bit wear on bone damage 11,40,91,108,109,169,178 ; the drill bit wear produces many unwanted complications in bone drilling such as elevating bone temperature above osteonecrosis level, 14,24,40,58,81,108,109,125,156,169,178 plunging into surrounding bone tissues, 9,45 and increasing thrust force and torque. 11,14,106,131,169 Furthermore, drill wear alters bone protein balance 151 and deteriorates-delamination 11 and surface roughness 11,58 -drilling hole quality.…”
Section: Influences Of Drill Bit Conditions On Bone Damage Drill Bit mentioning
confidence: 99%
“…39,53,91 Notwithstanding these controversies, to counter the threat of drill bit wear, improvements over the existing surgical drill bit design is necessitated. For example, wear-resistant material (e.g., zirconia 23,24,45,109 and HSS 87 ) could be adopted in designing a new drill bit. Also, the thermal cycling method could be applied to the surgical drill bit to improve the performance, durability, and longevity of materials.…”
Section: Influences Of Drill Bit Conditions On Bone Damage Drill Bit mentioning
confidence: 99%
See 1 more Smart Citation
“…However, Kim et al showed that lower drilling speeds do not increase the heat transferred to bone tissues despite the increasing working time [18]. The wear of dental implant drills have been previously analyzed by means of finite element analysis (FEA) [19] and scanning electron microscopic (SEM) and energy-dispersive x-ray spectroscopic examinations [20]; however, none of these measurement procedures allows an accurate analysis of surface and volumetric wear experienced by the dental implant drill after clinical use, because FEA analysis performs a digital simulation and the SEM examination allows only a superficial analysis, preventing the volumetric changes measurement. However, geomorphometric technique allows an accurate measurement of both surface and volumetric changes between the non-use and continued use dental implant drill.…”
Section: Introductionmentioning
confidence: 99%