2016
DOI: 10.1016/j.jece.2016.09.011
|View full text |Cite
|
Sign up to set email alerts
|

Comparison the sorption properties of clinoptilolite and synthetic zeolite during sorption strontium from the water solutions in static conditions: Sorption and quantitative determination of strontium by the method PIXE

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
3
0

Year Published

2018
2018
2024
2024

Publication Types

Select...
8

Relationship

1
7

Authors

Journals

citations
Cited by 18 publications
(10 citation statements)
references
References 6 publications
0
3
0
Order By: Relevance
“…The presence of impurities in the spectrum of hydrochloric acid is due to the composition of the carbon matrix. The carbon matrix composition was discussed in more detail in a previous publication [16].…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…The presence of impurities in the spectrum of hydrochloric acid is due to the composition of the carbon matrix. The carbon matrix composition was discussed in more detail in a previous publication [16].…”
Section: Resultsmentioning
confidence: 99%
“…Europium was excited by a proton beam with an energy Ep ≈ 1600 keV, an average current Ip ≈ 150 nA [14][15][16][17].…”
Section: Analytical Part Quantitative Determination Of Europium In Smentioning
confidence: 99%
“…Segregation increased the efficiency of the column to 0.69 when a combination of 250-300 and 500-600 µm particles were fluidized with a contact time of 1 min. Alotaibi et al 2023Alotaibi et al , 2022Șenilă et al 2023;Yuan et al 2023;Inan and Hiçsönmez, 2022;Inan, 2022;Jiménez-Reyes et al 2021;Zhang et al 2022;Kwon et al 2021;Prajitjitno et al 2021;Lehto et al 2019;Liang et al 2019;Misaelides et al 2019Misaelides et al , 2018Misaelides et al , 1995Fang et al 2017;Elizondo et al 2016;Levenets et al 2016; Brazilian Journal of Development, Curitiba, v.10, n.1, p. 1713-1799, jan., 2024 Lihareva et al 2015;Munthali et al 2015;Sato et al 2011;Camacho et al 2010;Matijašević et al 2006: Osmanlioglu, 2006Sato et al 1999;Rajec et al 1998;Mátel et al 1991.…”
Section: Applications Of Zns In Heavy Metal Disposalmentioning
confidence: 99%
“…Targets were placed in a cassette located in the irradiation chamber. Before conducting measurements, a vacuum was created in the chamber with a pressure of 10 -4 Pa. To excite characteristic X-ray radiation (XRR) of Cs, Sr, and Co atoms, a proton beam with a current of 200 nA and an energy of 1400 keV was used [12,14,15]. At this energy, the characteristic X-ray radiation of the L-series of cesium atoms and the K-series of strontium and cobalt is effectively excited.…”
Section: Analytical Part Of the Experimentsmentioning
confidence: 99%
“…XRR exited the chamber through a 25 μm thick beryllium foil window. In previous studies to determine the content of cesium, strontium, and cobalt ions, for the optimization of spectrometric conditions for XRR spectra formation, a collimator with hole diameters of Ø 1.5 mm and polyethylene absorbing films 150 μm thick were used [12,14,15]. X-ray spectra were processed using the WinQXAS code.…”
Section: Analytical Part Of the Experimentsmentioning
confidence: 99%