2020
DOI: 10.1016/j.agwat.2019.105847
|View full text |Cite
|
Sign up to set email alerts
|

Comparisons of spray characteristics between vertical impact and turbine drive sprinklers—A case study of the 50PYC and HY50 big gun-type sprinklers

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

3
14
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 24 publications
(17 citation statements)
references
References 36 publications
3
14
0
Order By: Relevance
“…The improvement was lower under high-pressure conditions because the water distribution already had a good uniformity. Ge et al [9] indicated that the maximum distribution uniformity coefficients of the vertical impact sprinkler can reach 80.5% under high-pressure conditions, and this was consistent with the results of this study. The maximum application rates in the overlap area were decreased from 18, 16, 16 and 15 mm•h −1 to 16, 14, 14 and 12 mm•h −1 with operating pressures of 300, 400, 500 and 600 kPa, respectively.…”
Section: Optimization and Validationsupporting
confidence: 93%
See 2 more Smart Citations
“…The improvement was lower under high-pressure conditions because the water distribution already had a good uniformity. Ge et al [9] indicated that the maximum distribution uniformity coefficients of the vertical impact sprinkler can reach 80.5% under high-pressure conditions, and this was consistent with the results of this study. The maximum application rates in the overlap area were decreased from 18, 16, 16 and 15 mm•h −1 to 16, 14, 14 and 12 mm•h −1 with operating pressures of 300, 400, 500 and 600 kPa, respectively.…”
Section: Optimization and Validationsupporting
confidence: 93%
“…The improvement was lower under highpressure conditions because the water distribution already had a good uniformity. Ge et al [9] indicated that the maximum distribution uniformity coefficients of the vertical impact sprinkler can Figure 7 compares the spatial water distribution before and after optimization with square layout, with 1.41 times radius of throw at different operating pressures. The figure shows that after the optimization of the blades' structure, the water distribution uniformity in the overlap area improved, especially under low-pressure conditions.…”
Section: Optimization and Validationmentioning
confidence: 99%
See 1 more Smart Citation
“…The VMDs of the sprinkler under different operating pressures are shown in Figure 7. The droplet diameter increased exponentially with distance from the sprinkler, in accordance with the previous studies [14,19,34]. However, the sprinklers of interest in these studies were impact sprinklers and FSPSs.…”
Section: Droplet Sizesupporting
confidence: 91%
“…Due to the low breakup degree of the jet flow under low working pressure, the specific power and application rate under 100 kPa were significantly higher than those under other working pressures (Figures 6 and 12). It is easy to lead a lower infiltration rate and increase the formation of surface seal and runoff [34]. Meanwhile, the specific power increased with increasing nozzle size.…”
Section: Discussionmentioning
confidence: 99%