2021
DOI: 10.1049/gtd2.12251
|View full text |Cite
|
Sign up to set email alerts
|

Compensation of negative sequence for a novel AC integrated power supply system of urban rail transit

Abstract: With the large‐scale increasing demand for passenger transportation, the alternating current (AC) 25 kV traction power supply system (TPSS) of electrified railway is introduced into the construction of urban rail transit in China instead of the direct current (DC) TPSS. In order to suppress the negative sequence current and cancel the neutral section at the exit of traction substation of the AC TPSS, a novel AC integrated power supply system (IPSS) of the urban rail transit based on single‐phase static var gen… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
9
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 13 publications
(9 citation statements)
references
References 19 publications
0
9
0
Order By: Relevance
“…Taking the current phase of traction load lagging the voltage phase under the traction condition as an example, the power factor is cos 𝜑 L , and the specific compensation principle is shown in Figure 2, U − are opposite in direction, negative sequence is fully compensated when they are equal in magnitude. With the rational design of the reactive currents emitted by three SVGs, the comprehensive compensation purpose of reactive power and negative sequence components may be achieved [10].…”
Section: Structure and Principle Of Continuous Co-phase Traction Powe...mentioning
confidence: 99%
See 2 more Smart Citations
“…Taking the current phase of traction load lagging the voltage phase under the traction condition as an example, the power factor is cos 𝜑 L , and the specific compensation principle is shown in Figure 2, U − are opposite in direction, negative sequence is fully compensated when they are equal in magnitude. With the rational design of the reactive currents emitted by three SVGs, the comprehensive compensation purpose of reactive power and negative sequence components may be achieved [10].…”
Section: Structure and Principle Of Continuous Co-phase Traction Powe...mentioning
confidence: 99%
“…The negative sequence components of the reactive currents emitted by the SVG are, trueİS1$\dot I_{{\rm{S}}1}^ - $, trueİS2$\dot I_{{\rm{S2}}}^ - $ and trueİS3$\dot I_{{\rm{S3}}}^ - $, which are combined into İSL$\dot I^{\prime}_{{\rm{SL}}}{^ -} $, İSL$\dot I^{\prime}_{{\rm{SL}}}{^ - }$ and İL$\dot I_{\rm{L}}{^ -} $are opposite in direction, negative sequence is fully compensated when they are equal in magnitude. With the rational design of the reactive currents emitted by three SVGs, the comprehensive compensation purpose of reactive power and negative sequence components may be achieved [10].…”
Section: Harmonic Models Of Continuous Co‐phase Traction Power Supply...mentioning
confidence: 99%
See 1 more Smart Citation
“…However, rail potential cannot always be directly grasped by the power company, especially the operation and maintenance department, and the rail potential is easily affected by the position of the measurement point which makes the method limited. In [12] and [13], the negative rail current was studied, both its suppression and exploitation methods have been proposed. There is a consensus among these studies that the neutral current is related to the frequent starting and braking of train.…”
Section: Introductionmentioning
confidence: 99%
“…It has a great impact on power systems such as generators, transformers, and relay protection. The safe and stable operation of power system is difficult to be guaranteed [2]- [3]. In order to reduce the impact of negative sequence current, the alternating commutation mode is adopted to connect the traction power supply system to the grid, which is different phases of electric energy fed by different traction substations for load use [4].…”
Section: Introductionmentioning
confidence: 99%