2020
DOI: 10.1016/j.engstruct.2020.110805
|View full text |Cite
|
Sign up to set email alerts
|

Composite dowels as load introduction devices in concrete-filled steel tubular columns

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

1
15
0

Year Published

2021
2021
2025
2025

Publication Types

Select...
9

Relationship

2
7

Authors

Journals

citations
Cited by 12 publications
(16 citation statements)
references
References 25 publications
1
15
0
Order By: Relevance
“…This relationship was composed of two main parts: an idealized relationship which can be consulted in EN 1992-1-1 [15] and a post-failure [16]. The formulae and fitting parameters required for the extension curve are described elsewhere [16,17]. The concrete in tension was represented using a crack-opening relationship suggested by Cornelissen et al [19], as shown in Fig 6b . Additional relationships to characterize the damage initiation in tension and compression must be specified in the CPD model.…”
Section: Materials Modelling Of Concretementioning
confidence: 99%
“…This relationship was composed of two main parts: an idealized relationship which can be consulted in EN 1992-1-1 [15] and a post-failure [16]. The formulae and fitting parameters required for the extension curve are described elsewhere [16,17]. The concrete in tension was represented using a crack-opening relationship suggested by Cornelissen et al [19], as shown in Fig 6b . Additional relationships to characterize the damage initiation in tension and compression must be specified in the CPD model.…”
Section: Materials Modelling Of Concretementioning
confidence: 99%
“…In the 1990s, Wurzer (1998) and Zapfe (2001) developed a new type shear connector with open cut-outs in the steel strip or called composite dowel. The Composite dowels can make full advantage of effective and economic combination of steel and concrete without using top steel flange (Cardoso et al, 2020; Classen et al, 2016; Classen and Gallwoszus, 2016; Seidl et al, 2013a).…”
Section: Introductionmentioning
confidence: 99%
“…During construction, the transversal reinforcement is easy to install and put into the designated position. Moreover, its bearing capacity is better than the PBL shear connectors, and exhibiting good anti-fatigue performance as well 10 13 . Researchers have carried out a series of static tests and theoretical studies on PZ shape composite dowel shear connectors in recent years.…”
Section: Introductionmentioning
confidence: 99%