2021
DOI: 10.1016/j.jobe.2020.101631
|View full text |Cite
|
Sign up to set email alerts
|

Comprehensive evaluation of thermal and energy performance of radiative roof cooling in buildings

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
17
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 34 publications
(17 citation statements)
references
References 50 publications
0
17
0
Order By: Relevance
“…The cities of Kunming, Hong Kong, Shanghai, Beijing, and Harbin can achieve energy saving rates of 9.3%, 7.1%, 4.1%, 3.3%, and 0.6% due to the different climates. 99 Even though the cooling in the winter period would increase the energy input while the cooling load savings surpassed the heating load penalties. A cool roof can save annual cooling energy of 33-57 USD m À2 for the topfloor residential units with a short payback period (< 6 months).…”
Section: Space Coolingmentioning
confidence: 99%
See 3 more Smart Citations
“…The cities of Kunming, Hong Kong, Shanghai, Beijing, and Harbin can achieve energy saving rates of 9.3%, 7.1%, 4.1%, 3.3%, and 0.6% due to the different climates. 99 Even though the cooling in the winter period would increase the energy input while the cooling load savings surpassed the heating load penalties. A cool roof can save annual cooling energy of 33-57 USD m À2 for the topfloor residential units with a short payback period (< 6 months).…”
Section: Space Coolingmentioning
confidence: 99%
“…For example, as shown in Figure 14B, the cooling load savings are generally higher than the heating load, resulting in positive annual energy savings. The cities of Kunming, Hong Kong, Shanghai, Beijing, and Harbin can achieve energy saving rates of 9.3%, 7.1%, 4.1%, 3.3%, and 0.6% due to the different climates 99 …”
Section: Applications and Challenges Of Pdrcmentioning
confidence: 99%
See 2 more Smart Citations
“…The MAC was inclined with an angle that was designed based on the characteristic of fluid thermal expansion which enhanced the convective velocity of the air inside the cavity. According to the researcher Pradhan, the convective velocity of the heated surface will increase as the angle of inclination increases (Abhijit et al, 2019;Chen and Lu, 2020). In this case, the heat energy trapped in the attic region will be transferred to the MAC which reduces the temperature inside the attic region.…”
Section: Comparison Of Attic Temperaturementioning