2018
DOI: 10.1049/iet-rpg.2018.5247
|View full text |Cite
|
Sign up to set email alerts
|

Comprehensive frequency regulation scheme for permanent magnet synchronous generator‐based wind turbine generation system

Abstract: Due to a growing penetration of permanent magnet synchronous generator-based wind turbine generation (PMSG-WTG) systems into the modern power grid, there is a strong interest in leveraging the potential capabilities of PMSG-WTG system to participate in the system frequency regulation during the grid event. In this work, a novel comprehensive frequency regulation (CFR) scheme is proposed specifically for rotor-speed-control-oriented PMSG-WTG systems. The step-wise inertial power response enables PMSG to perform… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4

Citation Types

0
15
0

Year Published

2019
2019
2022
2022

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 22 publications
(15 citation statements)
references
References 38 publications
0
15
0
Order By: Relevance
“…In the last decade, the direct-drive permeant magnet synchronous generator (D-PMSG) has been used in many industries, especially, for renewable energy applications [1][2][3], aircraft [4,5], and propulsion systems [6]. Normally, the stator resistance, d-q axis inductance, and permeant magnet flux linkage in the model of generator are constant by default, but in the actual operation process, the parameters of permeant magnet synchronous generator (PMSG) are affected by temperature, flux saturation, skin effect and so on, and these parameters are directly related to the performance of the controller.…”
Section: Introductionmentioning
confidence: 99%
“…In the last decade, the direct-drive permeant magnet synchronous generator (D-PMSG) has been used in many industries, especially, for renewable energy applications [1][2][3], aircraft [4,5], and propulsion systems [6]. Normally, the stator resistance, d-q axis inductance, and permeant magnet flux linkage in the model of generator are constant by default, but in the actual operation process, the parameters of permeant magnet synchronous generator (PMSG) are affected by temperature, flux saturation, skin effect and so on, and these parameters are directly related to the performance of the controller.…”
Section: Introductionmentioning
confidence: 99%
“…Based on the de-loaded control, the droop control is adopted to akin to the synchronous generators, which can provide minutes-term primary frequency support. In (Gao et al, 2019), a comprehensive frequency regulation scheme that combines the stepwise inertial control and variable-droop control is proposed. A coordinated control scheme that flexibly switches between additional power control, tracking curve control, and pitch angle adjustment control at different start-up stages is proposed, which can effectively improve insufficient frequency support.…”
Section: Introductionmentioning
confidence: 99%
“…But, it still required the parameter of wind turbines. In Gao et al (2019) a comprehensive frequency regulation that combines the step-wise inertial control and variable-droop control is present.…”
Section: Introductionmentioning