2017
DOI: 10.21307/acee-2017-026
|View full text |Cite
|
Sign up to set email alerts
|

Comprehensive On Site Thermal Diagnostics Of Buildings – Polish Practical Experience

Abstract: Savings of energy in buildings is a priority in many countries. The EU Member States took on the obligation to reach highly energy efficient building stock by 2050. Poland, as a member country of the EU, makes efforts to reduce energy consumption in the building sector. The Polish National Centre for Research and Development is an agency of the Minister of Science and Higher Education. It is the entity created as the platform for dialogue between the business and scientific communities. The Board of the Nation… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
10
0

Year Published

2017
2017
2024
2024

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 11 publications
(11 citation statements)
references
References 5 publications
0
10
0
Order By: Relevance
“…However, according to the adaptive model concept, these ranges of relative humidity and air temperature might be changeable based on the meteorological or climatological conditions [26]. • Visual Comfort: Assessment of the lighting performance is an activity within the scope of the overall diagnostic of the indoor environmental quality in buildings [27,28]. However, the "Lighting Handbook of the Illuminating Engineering Society" (IES) recommended that the lighting intensity at the working plane level in office spaces would range between 300 to 500 Lux [29].…”
Section: Technical Elements Of Performancementioning
confidence: 99%
“…However, according to the adaptive model concept, these ranges of relative humidity and air temperature might be changeable based on the meteorological or climatological conditions [26]. • Visual Comfort: Assessment of the lighting performance is an activity within the scope of the overall diagnostic of the indoor environmental quality in buildings [27,28]. However, the "Lighting Handbook of the Illuminating Engineering Society" (IES) recommended that the lighting intensity at the working plane level in office spaces would range between 300 to 500 Lux [29].…”
Section: Technical Elements Of Performancementioning
confidence: 99%
“…50 periods have uncertainty in the range of 10-20% and most of them are based on September data (but on July data also). As part of the work on the Strategic Research Project described in [2] a similar analysis for the studied building was made using the data of the reference season [14], which is milder in comparison with the actual climate of 2011 for Gliwice. Percentage differences from -50 to 30% were obtained.…”
Section: Calculations Based On Monthly Datamentioning
confidence: 99%
“…"The development of thermal diagnostics of buildings" was predominantly carried out in the Department of Heating, Ventilation and Dust Removal at Silesian University of Technology. A detailed description of the scope of the project is given in [1]. In the first steps, the project group has developed quick methods of building diagnostics for different building components, i.e.…”
Section: Introductionmentioning
confidence: 99%