Materials 1992
DOI: 10.1007/978-1-4757-9050-4_46
|View full text |Cite
|
Sign up to set email alerts
|

Compression and Shear Tests of Vacuum-Impregnated Composites at Cryogenic Temperatures

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
8
0

Year Published

1993
1993
2023
2023

Publication Types

Select...
7
2
1

Relationship

0
10

Authors

Journals

citations
Cited by 22 publications
(8 citation statements)
references
References 2 publications
0
8
0
Order By: Relevance
“…Details of other methods and their pros and cons, such as the shear-compression test, which was widely used in the US, 55,68,69 or the "doublelap shear test" (DLS), 70 which is particularly useful for assessing fatigue effects of the shear strength, can be found in the literature. 59,71,72 The focus on the mechanical rather than the electrical properties of these materials dates back to very early work showing that the dielectric breakdown remained rather unaffected under radiation compared to the mechanical performance.…”
Section: Methodsmentioning
confidence: 99%
“…Details of other methods and their pros and cons, such as the shear-compression test, which was widely used in the US, 55,68,69 or the "doublelap shear test" (DLS), 70 which is particularly useful for assessing fatigue effects of the shear strength, can be found in the literature. 59,71,72 The focus on the mechanical rather than the electrical properties of these materials dates back to very early work showing that the dielectric breakdown remained rather unaffected under radiation compared to the mechanical performance.…”
Section: Methodsmentioning
confidence: 99%
“…To avoid both the slippage problem and the load uncertainty problem, a test fixture shown in Fig. 2(b) was designed by Simon et al [22]. It consists of two identical right-angle trapezoidal blocks, respectively, at the top and the bottom of the fixture and one isosceles trapezoidal block at the center, and a rectangular slot is cut at the center of each tilt surface to hold the specimen.…”
Section: Methodsmentioning
confidence: 99%
“…The UTS tests were carried out according to the ASTM D3039, and the ILSS tests were determined by short-beam bending test according to the ASTM D2344. For the compressive shear (45 ) strength test, this is non-standard test, first proposed by Simon [6], and the test specimens were prepared by VPI process. The resin formula is the same as that of the SCC test sample using an adapted mold.…”
Section: F Mechanical Strength Testmentioning
confidence: 99%