2013
DOI: 10.2172/1220913
|View full text |Cite
|
Sign up to set email alerts
|

Computational Fluid Dynamics Analysis of Flexible Duct Junction Box Design

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
15
0

Year Published

2014
2014
2023
2023

Publication Types

Select...
3
2
2

Relationship

0
7

Authors

Journals

citations
Cited by 8 publications
(15 citation statements)
references
References 1 publication
0
15
0
Order By: Relevance
“…To assess the network quality, the parameter Skewness was used, which is one of the primary measures of network quality. Skewness determines how close a cell shape is to ideal shape [13]. The ideal element is in case of value 0, while 1 means a completely degenerated element.…”
Section: Meshquality Assessmentmentioning
confidence: 99%
“…To assess the network quality, the parameter Skewness was used, which is one of the primary measures of network quality. Skewness determines how close a cell shape is to ideal shape [13]. The ideal element is in case of value 0, while 1 means a completely degenerated element.…”
Section: Meshquality Assessmentmentioning
confidence: 99%
“…Recommended Configurations IBACOS' research found that pressure losses and the associated calculated EL values of junction boxes can vary considerably, based on the configuration, the number of flow splits desired, the location of the outlets in the box, the size of the box, the airflow through the box, and the incoming and outgoing velocities (Beach et al 2013). As a result of that research, IBACOS recommends that the following junction box configurations are optimal:…”
Section: 2mentioning
confidence: 99%
“…IBACOS used computational fluid dynamics software to explore and develop guidance to better control the airflow effects of factors that may impact pressure losses within junction boxes among various design configurations (Beach et al 2013). These recommendations can help to ensure that a system aligns more closely with the design and the occupants' comfort expectations.…”
Section: Introductionmentioning
confidence: 99%
“…Place the branch attached to the second junction box at the back of the first junction box. IBACOS used computational fluid dynamics software to explore and develop guidance to better control the airflow effects of factors that may impact pressure losses within junction boxes among various design configurations (Beach et al 2013). As a result, this measure guideline is intended to offer additional recommendations for optimizing flexible duct, constant-volume HVAC systems using junction boxes within ACCA Manual D guidance (Rutkowski 2009).…”
Section: Configurations Of More Than Four Outletsmentioning
confidence: 99%
“…ACCA Manual D assigns a 15-ft EL for a metal wye fitting, whereas a junction box receives a significantly higher EL of 95 ft for a reference velocity of 900 ft per minute (fpm). The technical report by Beach et al (2013) discusses this issue in more detail.…”
Section: 2mentioning
confidence: 99%