2009
DOI: 10.1016/j.jvir.2009.02.015
|View full text |Cite
|
Sign up to set email alerts
|

Computational Modeling of Blood Flow in the TrapEase Inferior Vena Cava Filter

Abstract: The authors have designed a computer model to study the hemodynamics of the TrapEase filter with various thrombi and trapping positions. The model offers advantages over in vitro techniques, specifically improved resolution and easy adaptation for new filter designs, thrombus morphologies and/or sizes, and flow parameters. The results agree with those of previous bench experiments that suggest the upstream trapping position of the TrapEase filter leads to a potentially thrombogenic region of stagnant and/or re… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

4
37
0

Year Published

2010
2010
2020
2020

Publication Types

Select...
6
1

Relationship

1
6

Authors

Journals

citations
Cited by 39 publications
(41 citation statements)
references
References 24 publications
4
37
0
Order By: Relevance
“…The model assumes that all vessels are straight and rigid, all thrombus are circular or elliptical, and flow through the IVC is steady; the applicability of these approximations is discussed elsewhere (e.g., [13,16]). It can be noted, however, that the design optimization methodology used here is broadly applicable to different sizes and shapes of clots.…”
Section: Discussionmentioning
confidence: 99%
See 3 more Smart Citations
“…The model assumes that all vessels are straight and rigid, all thrombus are circular or elliptical, and flow through the IVC is steady; the applicability of these approximations is discussed elsewhere (e.g., [13,16]). It can be noted, however, that the design optimization methodology used here is broadly applicable to different sizes and shapes of clots.…”
Section: Discussionmentioning
confidence: 99%
“…All vessels are taken to be straight and rigid (e.g., [12][13][14][15][16]), and the IVC has an inner diameter of 23mm, per the average cava diameter in [17]. The diameters and entry angles of the common iliac and renal veins into the IVC, as noted in Fig.…”
Section: Computational Modelmentioning
confidence: 99%
See 2 more Smart Citations
“…Unlike previous computational studies, which considered blood flow in idealized IVC geometries without IVC-IVC filter interactions [17,5,7,19,20], the present study addresses new aspects of IVC filter placement: 1) the in Keefe B. Manning BIO-13-1517…”
Section: Discussionmentioning
confidence: 99%