2010
DOI: 10.1007/s00066-010-2086-5
|View full text |Cite
|
Sign up to set email alerts
|

Computed Tomography as a Source of Electron Density Information for Radiation Treatment Planning

Abstract: The HU-rho(el) relationships predefined in TPS can be used for general-purpose CT systems operating at voltages close to 120 kV. For nontypical imaging systems (e.g., CBCT), the relationship can be significantly different and, therefore, it should always be measured and carefully analyzed before using CT data for treatment planning.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
32
0

Year Published

2011
2011
2021
2021

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 40 publications
(32 citation statements)
references
References 23 publications
0
32
0
Order By: Relevance
“…After the CT scans were obtained for FB (CT FB ), the EIH CT scans (CT EIH ) and EEH CT scans (CT EEH ) associated with ABC were performed. All CT scans were obtained in a spiral scan model (pitch = 0.938, table speed = 30 mm/s, reconstruction slice thickness = 3.0 mm) [26,27]. The CT images were transmitted to the treatment planning system Varian Eclipse V8.6.15 (Varian Medical Systems, Palo Alto, CA, USA) for target volume contouring and plan designing.…”
Section: Ct Simulation and Ptv Acquisitionmentioning
confidence: 99%
“…After the CT scans were obtained for FB (CT FB ), the EIH CT scans (CT EIH ) and EEH CT scans (CT EEH ) associated with ABC were performed. All CT scans were obtained in a spiral scan model (pitch = 0.938, table speed = 30 mm/s, reconstruction slice thickness = 3.0 mm) [26,27]. The CT images were transmitted to the treatment planning system Varian Eclipse V8.6.15 (Varian Medical Systems, Palo Alto, CA, USA) for target volume contouring and plan designing.…”
Section: Ct Simulation and Ptv Acquisitionmentioning
confidence: 99%
“…In order to exclude HU to ED conversion effects, the same calibration curve was established in Monaco. For this purpose HU determination of tissue substitutes was performed with the Gammex 467 phantom (Gammex RMI, UK) and the results converted using aforementioned equations [30].…”
Section: Dose Calculation Algorithms and Tpsmentioning
confidence: 99%
“…In external beam radiotherapy, computed tomography (CT) is the primary imaging modality for treatment planning (Chernak et al 1975, Pereira et al 2014, since it enables precise calcul ation of dose distributions (Seco and Evans 2006, Skrzyński et al 2010, Brock and Dawson 2014, and provides reference images allowing for pre-treatment positioning (Van den Berge et al 2000).…”
Section: Introductionmentioning
confidence: 99%