2012
DOI: 10.1111/j.1532-950x.2011.00950.x
|View full text |Cite
|
Sign up to set email alerts
|

Computed Tomography Findings in 32 Joints Affected with Severe Elbow Incongruity and Fragmented Medial Coronoid Process

Abstract: On CT, several features associated with severe elbow incongruity and concomitant FCP were detected, which were not found in normal joints or congruent joints affected by FCP.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

1
56
1
2

Year Published

2013
2013
2021
2021

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 33 publications
(60 citation statements)
references
References 32 publications
1
56
1
2
Order By: Relevance
“…Dogs with incongruent elbow joints and other pathological changes except MCD were excluded from this study. Elbow joint congruence was tested in agreement by Samoy, Gielen, and Caelenberg (), Samoy, Gielen, Saunders, Bree, and Van Ryssen () and Samoy, Van Vynckt, et al ().…”
Section: Methodsmentioning
confidence: 99%
See 2 more Smart Citations
“…Dogs with incongruent elbow joints and other pathological changes except MCD were excluded from this study. Elbow joint congruence was tested in agreement by Samoy, Gielen, and Caelenberg (), Samoy, Gielen, Saunders, Bree, and Van Ryssen () and Samoy, Van Vynckt, et al ().…”
Section: Methodsmentioning
confidence: 99%
“…Congruence measurements in a sagittal reconstruction in three places were performed to determine the distance between the elbow joint bones (Samoy, Gielen, & Caelenberg, ; Samoy, Gielen, Saunders, et al, ; Samoy, Van Vynckt, et al, ). The humeroulnar joint space was measured between the greatest concave point of the trochlear notch and the contiguous point of the humeral condyle.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…Três avaliadores, com níveis diferentes de experiência prática, sendo que o avaliador principal foi considerado o avaliador com maior experiência, avaliaram, em cego, as imagens tomográficas em formato DICOM (Digital Imaging and Communications in Medicine). Baseado no tamanho do degrau radioulnar na reconstrução sagital, a graduação para incongruência radioulnar foi realizada, conforme proposto por Samoy et al (2012). Foi elaborado um protocolo de avaliação na análise das imagens radiográficas e de TC, considerando sim para a presença da alteração, não para a ausência da alteração e não possível para a impossibilidade de identificação de determinada lesão.…”
Section: Methodsunclassified
“…Baseado no tamanho do degrau radioulnar na reconstrução sagital, uma graduação para incongruência foi realizada, considerando: articulação congruente (grau 0): degrau entre rádio e ulna entre 0 < 0,5mm; discreta incongruência (grau 1): 0,5mm <2,0mm; moderada incongruên-cia (grau 2): 2,0mm <3,0mm; importante incongruência (grau 3): 3mm ou mais (Samoy et al 2012).…”
Section: Introductionunclassified