“…It may be used when echo and CMR assessments are not definitive and to aid preprocedural planning. 26 Assessment of PR severity Determination of the PR severity is less well validated than determination of AR severity.…”
Section: Imaging Evaluation In Pr Pulmonary Valve Morphologymentioning
confidence: 99%
See 2 more Smart Citations
“…It may be used when echo and CMR assessments are not definitive and to aid preprocedural planning. 26 Assessment of PR severity Determination of the PR severity is less well validated than determination of AR severity.…”
Section: Imaging Evaluation In Pr Pulmonary Valve Morphologymentioning
confidence: 99%
“…69 CCT may also be helpful in assessing MV anatomy but it is major role in is the planning of intervention where it provides accurate assessment of the mitral annulus size, the presence and extent of calcification of the leaflets and subvalvular apparatus, the angle between the anterior MV and LVOT and the presence of coronary artery disease in younger patients. 26…”
Section: Aetiology and Mechanisms Of Mrmentioning
confidence: 99%
See 1 more Smart Citation
“…CT is not used as a primary diagnostic imaging method for evaluating cardiac valves mainly due to its insufficient temporal and spatial resolutions and high radiation exposure required for data acquisition throughout the entire cardiac cycle. Nevertheless, CT may be used for morphologic and functional assessments of cardiac valves in patients with CHD [ 109 ]. The number of the semilunar valve leaflets may be evaluated on CT.…”
Section: Valvementioning
confidence: 99%
“…X-ray based ex vivo CT is considered the most powerful technique to provide high spatial resolution of small structures (Liguori et al, 2015;Larsson et al, 2016;Mortensen et al, 2018;Litmanovich et al, 2019). Here we use µ-CT, which is capable of volumetric analysis with a voxel size <20 µm (Holdsworth et al, 2002;Clark et al, 2014;Senter-Zapata et al, 2016) to characterize the 3D morphology of the cardiac compartments and adjacent vessels.…”
Section: Micro-ct Analyses Reveal Outflow Tract Defects In Alk5a Mutantsmentioning