OBJECTIVE:
To evaluate the sensitivity and ability of computed tomography (CT) scan for diagnosing traumatic ankle arthrotomies compared with that of the saline load test (SLT).
METHODS:
Eleven cadaveric ankles were included in this study. Before intervention, a CT scan was obtained to confirm the absence of intra-articular air. Arthrotomies were created at the anterolateral, posterolateral, anteromedial, and posteromedial aspects of the ankle under fluoroscopic visualization. A postarthrotomy and postrange of motion CT scan was obtained to evaluate for the presence of intra-articular air. Each ankle then underwent a SLT with 60 mL of saline, where volumes provoking extravasation were recorded.
RESULTS:
Of the 11 included ankles, intra-articular air was detected in all 11 ankles by CT scan. All 11 ankles also demonstrated extravasation of saline through the arthrotomy site during SLT. Thus, the sensitivity for both CT scan and SLT for detecting ankle traumatic arthrotomy was 100%. The mean volume of saline needed for extravasation was 7.7 mL, with a range of 3–22 mL and a SD of 5.4.
CONCLUSIONS:
Given that CT scan was equally as sensitive to the SLT, this study presents good evidence that CT scan may be used for the detection of ankle traumatic arthrotomies.