Computer and telecommunications equipment room cooling: a review of literature

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
14
0

Year Published

2007
2007
2021
2021

Publication Types

Select...
5
2
1

Relationship

0
8

Authors

Journals

citations
Cited by 41 publications
(15 citation statements)
references
References 84 publications
1
14
0
Order By: Relevance
“…Effective energy saving measures such as employing highly efficient air conditioning systems [150,152,153], proper design of the building envelope [154,165,166], indoor airflow optimization [167], as well as the reduction of cooling loads through energy efficient BS electronic equipment and energy management monitoring [168] are some of the solutions that have received more attention in recent years. A study of BS cooling using a two-phase loop-type thermo-siphon system that was integrated inside the wall had been introduced by Nakao et al [166].…”
Section: Coolingmentioning
confidence: 99%
“…Effective energy saving measures such as employing highly efficient air conditioning systems [150,152,153], proper design of the building envelope [154,165,166], indoor airflow optimization [167], as well as the reduction of cooling loads through energy efficient BS electronic equipment and energy management monitoring [168] are some of the solutions that have received more attention in recent years. A study of BS cooling using a two-phase loop-type thermo-siphon system that was integrated inside the wall had been introduced by Nakao et al [166].…”
Section: Coolingmentioning
confidence: 99%
“…Generally, the PCB board of telecommunication equipment is cooled by air because of ease maintenance and good electrical insulation [1]. PCB surface temperature, and inlet and outlet air temperatures of the unit rack for the telecommunication equipment operated in the field were measured for a month.…”
Section: Performance Comparison Of the Air Cooled Unit With The Mpcm mentioning
confidence: 99%
“…The equipment installed in telecommunication equipment rooms consists of rackmounted units with chips on the PCB (printed circuit board) module. The power density and heat dissipation rate per unit area of the PCB module have increased with technological advancement in the telecommunication hardware [1][2][3]. A proper heat dissipation method from the PCB module of the unit rack of the telecommunication equipment is very important for reliable operation of electronic components.…”
Section: Introductionmentioning
confidence: 99%
“…Works with significant connections to multiple categories will be described in their primary category and noted in subsequent categories. A compendium of data center literature was presented by Schmidt and Shaukatullah [8], which compares the cooling, energy efficiency, humidity and contamination requirements between computer and telecommunication equipment rooms and also serves as a historical perspective considering the rapid growth in data center power density.…”
Section: Review Of Numerical Modelingmentioning
confidence: 99%