2005
DOI: 10.1007/s00586-005-0992-5
|View full text |Cite
|
Sign up to set email alerts
|

Computer-assisted screw insertion into the first sacral vertebra using a three-dimensional image intensifier: results of a controlled experimental investigation

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

1
15
0
2

Year Published

2007
2007
2018
2018

Publication Types

Select...
4
4

Relationship

0
8

Authors

Journals

citations
Cited by 31 publications
(18 citation statements)
references
References 34 publications
(23 reference statements)
1
15
0
2
Order By: Relevance
“…An additional ilioiliac tension band plate or, technically more demanding, a second screw into S2 are the treatment alternatives of choice in our centre to achieve sufficient fracture stabilisation and early mobilisation. Recent studies propose computer-assisted procedures in pelvic surgery to reduce the risk of screw misplacement based on previous experiences in spinal surgery [5,7]. Our study data suggest that the use of navigation is associated with a lower screw misplacement rate compared to the standard procedure.…”
Section: Malpositionmentioning
confidence: 59%
See 1 more Smart Citation
“…An additional ilioiliac tension band plate or, technically more demanding, a second screw into S2 are the treatment alternatives of choice in our centre to achieve sufficient fracture stabilisation and early mobilisation. Recent studies propose computer-assisted procedures in pelvic surgery to reduce the risk of screw misplacement based on previous experiences in spinal surgery [5,7]. Our study data suggest that the use of navigation is associated with a lower screw misplacement rate compared to the standard procedure.…”
Section: Malpositionmentioning
confidence: 59%
“…More recently, a number of reports also proposed navigated procedures for fixation of unstable pelvic ring injuries, predominantly of the posterior pelvis [5][6][7]. The current standard for treatment of those injuries is the percutaneous iliosacral screw fixation using fluoroscopic techniques according to Matta and Saucedo [8].…”
Section: Introductionmentioning
confidence: 99%
“…In orthopedic surgery, it is used in spine and pelvic surgery in particular, and has grown considerably in popularity [7][8][9]. Therapy for fractures of the scaphoid is an interesting indication for CAS, although it also involves some potential difficulties.…”
Section: Discussionmentioning
confidence: 99%
“…The clinical relevance of this information may be of particular importance when considered in conjunction with other potential sources of error. While the clinical relevance of these factors has been found to be less critical when using navigation for spine or pelvic surgery [6,14], an awareness of these potential sources of error will allow the surgeon to address and reduce these problems [13,15]. Metallic artifacts were not found to significantly affect the precision of registration with fluoroscopybased navigation.…”
Section: Discussionmentioning
confidence: 99%
“…This is what allows the navigation system to generate the position and orientation of the 3D data set in space. The value of this device has been demonstrated in several procedures, including the drilling of osteochondral lesions in the talus [4], the placement of pedicle screws for spine surgery [5], sacroiliac screw placement in the pelvis [6], and tumor surgery [7]. As with most navigation systems, registration and data acquisition are important steps in Iso-C 3D -based navigation, and are subject to several potential sources of error.…”
Section: Introductionmentioning
confidence: 99%