2015
DOI: 10.1016/j.jmps.2014.12.003
|View full text |Cite
|
Sign up to set email alerts
|

Computing elastic moduli on 3-D X-ray computed tomography image stacks

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
11
0

Year Published

2015
2015
2018
2018

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 24 publications
(11 citation statements)
references
References 31 publications
0
11
0
Order By: Relevance
“…Both are 4.62 lm/ pixel resolution images, approximately 1000 9 1000 pixels in size, black is pore space, white is solid backbone, and gray is the uniform outer matrix material that has given and known elastic moduli Fig. 7 Schematic of X-ray CT cylindrical stack of images embedded into a rectangular box of known moduli material material, are used together with exact composite theory for a periodic array of right cylinders in a matrix to extract the effective moduli of just the inner foam cylinder [26]. This method, which has been thoroughly tested [26], allowed us to use all of the microstructural information from the X-ray CT images and did not require reduction of the analyzed volume to a smaller cubic sub-sample of the image cylinder.…”
Section: New Finite Element Techniquementioning
confidence: 99%
See 4 more Smart Citations
“…Both are 4.62 lm/ pixel resolution images, approximately 1000 9 1000 pixels in size, black is pore space, white is solid backbone, and gray is the uniform outer matrix material that has given and known elastic moduli Fig. 7 Schematic of X-ray CT cylindrical stack of images embedded into a rectangular box of known moduli material material, are used together with exact composite theory for a periodic array of right cylinders in a matrix to extract the effective moduli of just the inner foam cylinder [26]. This method, which has been thoroughly tested [26], allowed us to use all of the microstructural information from the X-ray CT images and did not require reduction of the analyzed volume to a smaller cubic sub-sample of the image cylinder.…”
Section: New Finite Element Techniquementioning
confidence: 99%
“…7 Schematic of X-ray CT cylindrical stack of images embedded into a rectangular box of known moduli material material, are used together with exact composite theory for a periodic array of right cylinders in a matrix to extract the effective moduli of just the inner foam cylinder [26]. This method, which has been thoroughly tested [26], allowed us to use all of the microstructural information from the X-ray CT images and did not require reduction of the analyzed volume to a smaller cubic sub-sample of the image cylinder. The exact solution for the composite elastic moduli of a periodic array composite of right cylinders in a matrix, where both cylinder and matrix are uniform linear elastic isotropic materials, is a function of the volume fraction of cylinders and the elastic moduli of the two phases [26,53].…”
Section: New Finite Element Techniquementioning
confidence: 99%
See 3 more Smart Citations