Conceptual Design and Performance Evaluation of a 35-kV/500-A Flux-Coupling-Type SFCL for Protection of a DFIG-Based Wind Farm

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
13
0

Year Published

2018
2018
2023
2023

Publication Types

Select...
9

Relationship

2
7

Authors

Journals

citations
Cited by 33 publications
(13 citation statements)
references
References 28 publications
0
13
0
Order By: Relevance
“…can be rewritten as: This kind of FCL was proposed and applied into the renewable energy integration process. Relevant studies are shown in [55]- [58]. The fault current reduction rate can be 25.8% under 100 mH L 2 case and with the rise in L 2 value, the current can be reduced more effectively.…”
Section: B External Circuit Topology Analysismentioning
confidence: 96%
“…can be rewritten as: This kind of FCL was proposed and applied into the renewable energy integration process. Relevant studies are shown in [55]- [58]. The fault current reduction rate can be 25.8% under 100 mH L 2 case and with the rise in L 2 value, the current can be reduced more effectively.…”
Section: B External Circuit Topology Analysismentioning
confidence: 96%
“…The impacts of transition resistance Rg on the accuracy of the proposed technique in cases of internal and external fault are studied. It is studied in case of a three- A comparison between the proposed protection technique with others protection techniques [30][31][32] is provided as follows: Chen et al [30] have presented superconducting fault current limiter (SFCL) protection system to suppress the fault current of DFIG-Based wind farm. Wang et al [31] have proposed a flexible fault ride through strategy to allow a few wind turbine generators to trip and maintains the connection to grid of most generators during fault.…”
Section: Impacts Of Transition Resistancementioning
confidence: 99%
“…In the literature, the protection technique for large-scale wind farm attracts the interest of researchers, where the most worrynty problem of wind farm generators is the cascading trip events caused by occurrence of different faults, which may propagate and cause isolation of all wind turbine generators over very large area [27][28][29][30][31][32].…”
Section: Introductionmentioning
confidence: 99%
“…Regarding the application of a FCL in a DFIG, studies focus on bridge-type [2326] and superconducting-type FCLs [2734]. In [23], a bridge-type FCL with bypass resistor is applied in a DFIG.…”
Section: Introductionmentioning
confidence: 99%