2004
DOI: 10.1016/j.mineng.2003.08.013
|View full text |Cite
|
Sign up to set email alerts
|

Conceptual process design as a prerequisite for solving environmental problems; a case study of molybdenum removal and recovery from wastewater

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
7
0

Year Published

2007
2007
2023
2023

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 24 publications
(8 citation statements)
references
References 2 publications
1
7
0
Order By: Relevance
“…A (Swinkels et al, 2004). The low background partition coefficient (D Mo =1.5×10 −4 ) agrees first with an anionic Mo precipitation pathway within the CaCO 3 shell.…”
Section: Evolution Of the Mo Partitioning Between The Shell And The Ssupporting
confidence: 53%
“…A (Swinkels et al, 2004). The low background partition coefficient (D Mo =1.5×10 −4 ) agrees first with an anionic Mo precipitation pathway within the CaCO 3 shell.…”
Section: Evolution Of the Mo Partitioning Between The Shell And The Ssupporting
confidence: 53%
“…A number of authors have sought to develop design methodologies that overcome this flaw [41]. Azapagic et al [21] go some way to addressing the ''after-thought'' or ''compliance only'' approach to design.…”
Section: Design Methodologiesmentioning
confidence: 99%
“…Molybdenum is mainly used in metallurgical applications as an alloying element in the production of stainless steel or castiron alloys (Barceloux 1999), and in the production of flame retardants, pigments and catalysts for high temperature chemical processes. The molybdate ion MoO 4 2-, the most common oxyanion of molybdenum, occurs in various types of wastewaters, like wastewater from a styrene monomer plant (1000 mg/l) (Swinkels et al, 2004), scrubber effluent of a municipal solid waste incinerator (0.95 mg/l) (Lievens et al, 2010) and mining water (, 0.1 to 2.2 mg/l) (Dessouki et al, 2005;Panayotova and Panayotov, 2004;Rojas and Vandecasteele, 2007). Traditional industrial wastewater treatment plants remove cations (e.g.…”
Section: Introductionmentioning
confidence: 99%
“…At high concentrations, oxyanions can be precipitated as their Ca-metalates, but this usually leaves rather high residual concentrations (Swinkels et al, 2004). Adsorption on goethite (a-FeOOH) and akageneite (b-FeOOH), is efficient for the removal of different oxyanions at low concentrations (Rovira et al, 2008Watkins et al, 2006;Wainipee et al, 2010).…”
Section: Introductionmentioning
confidence: 99%