2007
DOI: 10.1016/j.ophtha.2007.01.018
|View full text |Cite
|
Sign up to set email alerts
|

Concordance of Diurnal Intraocular Pressure between Fellow Eyes in Primary Open-Angle Glaucoma

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

2
25
0
3

Year Published

2008
2008
2016
2016

Publication Types

Select...
5
3

Relationship

0
8

Authors

Journals

citations
Cited by 38 publications
(30 citation statements)
references
References 18 publications
2
25
0
3
Order By: Relevance
“…This is similar to that found in earlier studies. [192021] This pattern was less obvious in eyes on treatment with PGA similar to that reported previously. [1920]…”
Section: Discussionsupporting
confidence: 87%
“…This is similar to that found in earlier studies. [192021] This pattern was less obvious in eyes on treatment with PGA similar to that reported previously. [1920]…”
Section: Discussionsupporting
confidence: 87%
“…Reports on the symmetry of diurnal curves between the right and left eyes have been conflicting, but the most recent studies have found strong correlations of IOP fluctuations between the fellow eyes in patients with untreated glaucoma (r = 0.84) and ocular hypertensive patients (r = 0.72) using Goldmann applanation tonometry. 21,22 Nevertheless, asymmetric fluctuations between the right and left eyes do occur in both untreated glaucoma patients and older healthy individuals, with estimates of the prevalence of this phenomenon varying widely. [21][22][23][24] These variations may account for the fact that several controls in our study had asymmetric IOP, whereas many glaucoma patients were observed to have symmetrical IOP with only 1 measurement.…”
Section: Discussionmentioning
confidence: 99%
“…21,22 Nevertheless, asymmetric fluctuations between the right and left eyes do occur in both untreated glaucoma patients and older healthy individuals, with estimates of the prevalence of this phenomenon varying widely. [21][22][23][24] These variations may account for the fact that several controls in our study had asymmetric IOP, whereas many glaucoma patients were observed to have symmetrical IOP with only 1 measurement. The value of IOP asymmetry as a diagnostic consideration should be weighted heavily in patients who show consistent IOP asymmetry on repeat clinic visits, and especially if those measurements are recorded within 2 hours of the same time of the day as the baseline IOP.…”
Section: Discussionmentioning
confidence: 99%
“…[28][29][30][31] Note, however, that 24-h IOP in HTG eyes showed striking concordance of IOP variation between fellow eyes of 1.6-2.0 mmHg, and the estimated probability of a 2 mmHg difference was 68-90% and a 3 mmHg difference was 78-95% for all time intervals studied. 32 More recently, these same researchers looked at the diurnal IOP fluctuation in untreated glaucoma suspect (GS) and NTG eyes. 33 They took six IOP measurements from 7 AM to 10 PM to evaluate the concordance of IOP between fellow eyes.…”
Section: Asymmetry Of Disease and Iopmentioning
confidence: 99%