2014
DOI: 10.1007/s10973-014-4276-3
|View full text |Cite
|
Sign up to set email alerts
|

Condition monitoring of transformer oil using thermal analysis and other techniques

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1

Citation Types

0
14
0

Year Published

2016
2016
2021
2021

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 35 publications
(14 citation statements)
references
References 40 publications
0
14
0
Order By: Relevance
“…Traditionally, mineral oils [1] are used as the electroinsulating fluid in the transformers, a strong biodegradable petroleum derivative [2], which, although having acceptable physical and dielectric characteristics and a relatively low cost, has a number of disadvantages such as: limited thermal stability [3][4][5][6][7][8], corrosive aggressivity due to sulfur content [8][9][10][11][12][13][14][15][16][17], reduced compatibility with the cellulose from Kraft paper -furanic products formation [18][19][20][21][22], relatively low flammability (below 150 o C) and excessive flammable gases formation [30] (high risk of explosions and devastating fires), etc. To increase thermal stability and to reduce the corrosive aggressiveness of electro-insulating oils, manufacturers often use antioxidant additives and / or corrosion inhibitors [15][16][17]31].…”
mentioning
confidence: 99%
“…Traditionally, mineral oils [1] are used as the electroinsulating fluid in the transformers, a strong biodegradable petroleum derivative [2], which, although having acceptable physical and dielectric characteristics and a relatively low cost, has a number of disadvantages such as: limited thermal stability [3][4][5][6][7][8], corrosive aggressivity due to sulfur content [8][9][10][11][12][13][14][15][16][17], reduced compatibility with the cellulose from Kraft paper -furanic products formation [18][19][20][21][22], relatively low flammability (below 150 o C) and excessive flammable gases formation [30] (high risk of explosions and devastating fires), etc. To increase thermal stability and to reduce the corrosive aggressiveness of electro-insulating oils, manufacturers often use antioxidant additives and / or corrosion inhibitors [15][16][17]31].…”
mentioning
confidence: 99%
“…Power transformer oil undergoes continuous deterioration and degradation because of electrical, thermal, mechanical, and environmental stresses occurring during operation [4]. Therefore any deterioration in the oil can lead to premature failure of the equipment.…”
Section: Introductionmentioning
confidence: 99%
“…Megger OTS 100 AF/2 installation for breakdown testing the mineral: (a) general view, (b) testing oil tank.4.2 Ageing RateVarious physicochemical and electric properties were measured to detect changes and determine the rates of ageing of the fluids[19]: Dissipation Factor (Tan δ), Resistivity, Total acid number (TAN) and Water Content in both new and regenerated insulating fluids. The ageing rates were assessed according to the equations (1)-(4). The reference values were obtained with initial new and regenerated oils samples.…”
mentioning
confidence: 99%
“…It should be underlined that, further to the thermooxidative ageing of the oil transformers [40][41][42][43][44][45][46] and the degradation of the electro insulating paper, highly determined by the dissolved oxygen and the humidity of the oil transformer, several toxic furfural products [47][48][49][50] and / or of flammable gases are produced [51][52][53][54][55][56][57][58] which may lead to the explosion of the oil transformer followed by devastating wildfires [55,57].…”
mentioning