2014
DOI: 10.1016/j.electacta.2014.01.041
|View full text |Cite
|
Sign up to set email alerts
|

Conductance measurement of carboxylic acids binding to palladium nanoclusters by electrochemical jump-to-contact STM break junction

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
21
2

Year Published

2015
2015
2021
2021

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 33 publications
(23 citation statements)
references
References 62 publications
0
21
2
Order By: Relevance
“…Current-voltage curves can also be recorded by pausing the retraction with the molecule bridge in place. A more recent development of the STM break junction technique is the STM jump-to-contact method developed by the Mao group (26)(27)(28). In this method, a foreign metal is electrodeposited on the STM tip, and then as the tip approaches the surface under electrochemical potential control metal can be transferred to the substrate.…”
Section: Figurementioning
confidence: 99%
“…Current-voltage curves can also be recorded by pausing the retraction with the molecule bridge in place. A more recent development of the STM break junction technique is the STM jump-to-contact method developed by the Mao group (26)(27)(28). In this method, a foreign metal is electrodeposited on the STM tip, and then as the tip approaches the surface under electrochemical potential control metal can be transferred to the substrate.…”
Section: Figurementioning
confidence: 99%
“…Since the molecule was also present in the medium, molecular contacts could be formed after rupture of the metallic contacts. Our previous studies have already proved that the single molecular conductance with nanocluster measured by the current ECSTM-BJ method is the same as that of molecule junctions with bulk metal on the tip and substrate [28]. This demonstrated that Ag-Molecule-Ag junctions were obtained.…”
Section: Results and Discussion 31 Conductance Of Dcb And Bda Contacmentioning
confidence: 58%
“…A Pt wire was used as the counter electrode, while Cu and Ag wires were used as the reference electrodes for Cu and Ag contacts, respectively. All conductance measurements were carried out on the modified Nanoscope IIIa STM (Veeco, US) [15,17,28]. The procedure of the single-molecule conductance measurement was given in detail in our previous work [28].…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…So far, well‐studied molecular junction systems most often have symmetric configurations, for instance using molecules terminated with similar anchoring groups at each extremity of the junction, including dithiol, diamine and dicarboxylic acidetc. Likewise, the majority of single‐molecule electrical studies have used the same metal contact types on either respective side, with gold being the most common, although other electrodes have been used such as Cu and Ag etc.…”
Section: Introductionmentioning
confidence: 99%