2012
DOI: 10.1111/j.1532-849x.2011.00811.x
|View full text |Cite
|
Sign up to set email alerts
|

Condylar Guidance: Correlation between Protrusive Interocclusal Record and Panoramic Radiographic Image: A Pilot Study

Abstract: Within the limitations of this study, it was concluded that the protrusive condylar guidance angles obtained by panoramic radiograph may be used in programming semi-adjustable articulators.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3

Citation Types

0
56
1
2

Year Published

2012
2012
2024
2024

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 35 publications
(59 citation statements)
references
References 20 publications
0
56
1
2
Order By: Relevance
“…The panoramic radiographic image was taken with the Frankfurt horizontal plane parallel to the floor of the mouth; a cephalostat was used to align the head in that position, as in Tannamala et al 14 The radiograph was made using a ProMax ® radiographic unit (Planmeca, Helsinki, Finland 2005) at 74 kVp and 10 mA. 9,14 The method was the same as that described previously by Loster et al 15 The chosen digital image was converted to analog and printed on A4 size (ISO 216) paper using an Epson Stylus Photo 1400 (Seiko Epson Corporation, Japan, 2007) inkjet printer; the resolution used was 2880 × 1440 dots per inch.…”
Section: Methodsmentioning
confidence: 99%
See 3 more Smart Citations
“…The panoramic radiographic image was taken with the Frankfurt horizontal plane parallel to the floor of the mouth; a cephalostat was used to align the head in that position, as in Tannamala et al 14 The radiograph was made using a ProMax ® radiographic unit (Planmeca, Helsinki, Finland 2005) at 74 kVp and 10 mA. 9,14 The method was the same as that described previously by Loster et al 15 The chosen digital image was converted to analog and printed on A4 size (ISO 216) paper using an Epson Stylus Photo 1400 (Seiko Epson Corporation, Japan, 2007) inkjet printer; the resolution used was 2880 × 1440 dots per inch.…”
Section: Methodsmentioning
confidence: 99%
“…9,14 The method was the same as that described previously by Loster et al 15 The chosen digital image was converted to analog and printed on A4 size (ISO 216) paper using an Epson Stylus Photo 1400 (Seiko Epson Corporation, Japan, 2007) inkjet printer; the resolution used was 2880 × 1440 dots per inch. One copy was provided to each of the participants, who were recruited from the Prosthodontic Department of the Jagiellonian University.…”
Section: Methodsmentioning
confidence: 99%
See 2 more Smart Citations
“…But in Tannamala et al's research, 2 we feel there may be a few problems. First, the author used a method similar to Gilboa et al, 1 by depicting a line between “the most superior and the most inferior points of the curvatures.” 2 But where were the curvatures? And what did the curvatures stand for?…”
mentioning
confidence: 89%