2019
DOI: 10.4028/www.scientific.net/kem.821.59
|View full text |Cite
|
Sign up to set email alerts
|

Connection Performance of Bolted Aluminum Alloy Honeycomb Panel-Beam Composite Structure

Abstract: A convenient and reliable connection between panels and beams was investigated for collaborative work of single-layer composite reticulated shell structure in which aluminum alloy honeycomb panels participate. In the paper, the "self-tapping bolt" connection was adopted to realize the "tight fit" performance of connection effectively in the composite structure. Through three groups of bearing capacity test on 1.5 m×3 m square meters of the aluminum alloy honeycomb panel-square tube beam combined structure, the… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
0
0

Year Published

2022
2022
2022
2022

Publication Types

Select...
1

Relationship

0
1

Authors

Journals

citations
Cited by 1 publication
(3 citation statements)
references
References 5 publications
0
0
0
Order By: Relevance
“…1 Except for the top timber board of the L1 group, which had no obvious damage, the top surface of the board of all other specimens had longitudinal cracks (splitting) due to compression, and some of the boards of the specimens were crushed. 2 The stress at the lower edge of the I-beam entered the flow amplitude stage, but the boards did not fracture. The composite beam connection was weak, and the stiffness was low due to the relatively few bolts assembled in the L1 group.…”
Section: Discussionmentioning
confidence: 97%
See 2 more Smart Citations
“…1 Except for the top timber board of the L1 group, which had no obvious damage, the top surface of the board of all other specimens had longitudinal cracks (splitting) due to compression, and some of the boards of the specimens were crushed. 2 The stress at the lower edge of the I-beam entered the flow amplitude stage, but the boards did not fracture. The composite beam connection was weak, and the stiffness was low due to the relatively few bolts assembled in the L1 group.…”
Section: Discussionmentioning
confidence: 97%
“…These parameters satisfy the following basic assumptions: 1 The longitudinal horizontal shear force between the timber-steel interface was proportional to the relative slip. 2 The influence of friction at the timber-steel interface on the relative slip was negligible. 3 The influence of preload applied on bolts on the relative slip of timber-steel composite beams was negligible.…”
Section: Calculation Of Bolts Relative Slip In Elastic Statementioning
confidence: 98%
See 1 more Smart Citation