2009 IEEE International Symposium on Circuits and Systems 2009
DOI: 10.1109/iscas.2009.5118178
|View full text |Cite
|
Sign up to set email alerts
|

Constant voltage control of high voltage high frequency power supply for ozone quantity adjustment

Abstract: This paper proposes the high frequency high voltage power supply for an ozone generator using a phase-shift pulse width modulation (PWM) full bridge inverter. The circuit operation is fully described. The high frequency transformer and ozone generator mathematical models are also included for preliminarily calculating of instantaneous voltages and currents. The proposed system simulation using the MATLAB /SIMULINK software package is given. In order to ensure that zero voltage switching (ZVS) mode always opera… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

1
2
0

Year Published

2010
2010
2014
2014

Publication Types

Select...
3
3

Relationship

1
5

Authors

Journals

citations
Cited by 8 publications
(3 citation statements)
references
References 8 publications
1
2
0
Order By: Relevance
“…From the results, it can be deduced that the performance of the ozone generator (both in terms of lower initiation voltage and higher yield), is superior when operated at higher frequency. These observations are consistent with the findings from other researchers, for example [6, 27].…”
Section: Resultssupporting
confidence: 94%
“…From the results, it can be deduced that the performance of the ozone generator (both in terms of lower initiation voltage and higher yield), is superior when operated at higher frequency. These observations are consistent with the findings from other researchers, for example [6, 27].…”
Section: Resultssupporting
confidence: 94%
“…In these circuits, the inductance is placed at the secondary of the transformer to stabilize the discharge. In [14]- [17], a full bridge inverter using a resonant inductor at the primary side is used to reduce the tuned resonant frequency. For both cases, the presence of the inductor increases the complexity of the circuit and reduces its efficiency.…”
Section: Introductionmentioning
confidence: 99%
“…Many converter topologies have been proposed in order to improve efficiency and reduce size [3,7]. One of those is based on the voltage source type IGBT resonant inverter [3][4][5][6][7][8][9][10][11][12]. This technique offers soft switching, reduced losses, and electro interference (EMI) / radio frequency interference (RFI).…”
Section: Introductionmentioning