2023
DOI: 10.1016/j.jmmm.2022.170304
|View full text |Cite
|
Sign up to set email alerts
|

Construction of a Hall effect scanning magnetic microscope using permanent magnets for characterization of rock samples

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
5
0

Year Published

2024
2024
2024
2024

Publication Types

Select...
4

Relationship

1
3

Authors

Journals

citations
Cited by 4 publications
(5 citation statements)
references
References 23 publications
0
5
0
Order By: Relevance
“…Additionally, to test the capabilities of the MSM, a study was conducted on a rock from the Jurassic-Triassic basaltic dike cluster, which was extracted from the western edge of the Parnaíba Basin and identified as Rock Sample, presented in Figure 5d. Regarding the samples, relevant information to be provided is as follows: the double iron sample was prepared using iron oxide powder, identified as Supermagna RW 222 from the company Metal-Chek, assumed to be 96% magnetite; the triple magnetite sample consisted of magnetic microparticles of 99% magnetite; the nickel sample was a nickel wire with 99.9% purity, previously used in other works for calibration [11]. All samples were used for test measurements, with analysis by the Mapper program (Developed for this study).…”
Section: Test Analysismentioning
confidence: 99%
See 4 more Smart Citations
“…Additionally, to test the capabilities of the MSM, a study was conducted on a rock from the Jurassic-Triassic basaltic dike cluster, which was extracted from the western edge of the Parnaíba Basin and identified as Rock Sample, presented in Figure 5d. Regarding the samples, relevant information to be provided is as follows: the double iron sample was prepared using iron oxide powder, identified as Supermagna RW 222 from the company Metal-Chek, assumed to be 96% magnetite; the triple magnetite sample consisted of magnetic microparticles of 99% magnetite; the nickel sample was a nickel wire with 99.9% purity, previously used in other works for calibration [11]. All samples were used for test measurements, with analysis by the Mapper program (Developed for this study).…”
Section: Test Analysismentioning
confidence: 99%
“…For this purpose, a program in MATLAB, identified as Mapper, was developed. The Mapper program has been previously used and described in [11]. The sample to be used in the test case was set up, consisting of a nickel wire with 99.9% purity.…”
Section: Data Treatmentmentioning
confidence: 99%
See 3 more Smart Citations