2007
DOI: 10.1016/j.electacta.2007.06.058
|View full text |Cite
|
Sign up to set email alerts
|

Construction of an amperometric pyruvate oxidase enzyme electrode for determination of pyruvate and phosphate

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
17
0

Year Published

2009
2009
2019
2019

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 40 publications
(17 citation statements)
references
References 24 publications
0
17
0
Order By: Relevance
“…[20] Amperometric biosensors are rapid and sensitive, but suffer from interference. [23] The mass spectrometric and enzymatic methods show good selectivity and sensitivity; both of them would be more promising if their relative high cost can be reduced. [20] Because of the improved spectroscopic properties and labeling conditions of the reagent RBPH, our proposed method may offer a new choice for the simple, selective, and sensitive determination of pyruvic acid.…”
Section: Linearitymentioning
confidence: 99%
See 1 more Smart Citation
“…[20] Amperometric biosensors are rapid and sensitive, but suffer from interference. [23] The mass spectrometric and enzymatic methods show good selectivity and sensitivity; both of them would be more promising if their relative high cost can be reduced. [20] Because of the improved spectroscopic properties and labeling conditions of the reagent RBPH, our proposed method may offer a new choice for the simple, selective, and sensitive determination of pyruvic acid.…”
Section: Linearitymentioning
confidence: 99%
“…Comparison with other methods: Several methods for determining pyruvic acid have been developed recently, including mass spectrometric methods, [22] amperometric biosensors based on pyruvate oxidase, [23] indirect amperometric capillary analysis, [24] and enzymatic fluorescence capillary analysis. [20] Amperometric biosensors are rapid and sensitive, but suffer from interference.…”
Section: Linearitymentioning
confidence: 99%
“…In the following decades, the immobilization of enzyme became a key issue in developing the enzyme-based biosensor. Generally speaking, the immobilized methods (Cunningham, 1998) of enzyme include adsorption (Chu et al, 2007;Ekanayake et al, 2007), entrapment (Ngounou et al, 2007;Seo et al, 2007), cross-linking (Akyilmaz & Yorganci, 2007) and covalent bonding (Lin et al, 2007a;Seo et al, 2007). For adsorption, the enzyme was attached on the electrode by the attractive force of hydrogen bonds or opposite charges, such as nylon (Gamati et al, 1991) and ion exchange resin (Zhujun & Seitz, 1986), but it did not form a good adhesive force between biomolecules and a transducer.…”
Section: The Immobilization Of Enzymes and Mediatorsmentioning
confidence: 99%
“…But most of these analytical techniques are often limited to low sensitivity, less improved detection limits, small sensitivity, negligible interference from real sample matrix, cost and/or fast response time for selective determination of phosphorous species [16][17][18][19][20][21][22][23][24][25][26][27][28]. Among these analytical techniques, CL can be considered as a promising detection system [15].…”